OVP05: ON/OFF
open/close OVP
OVP05?
Query the OVP voltage value
VSLOPE05:31 .5
Set the output voltage slope to be 31.SV/100uS
VSLOPE05?
Query the output voltage slope
ISLOPE05:1 .5
Set the slope oft he output current to be 1.5A/100uS
ISLOPE05?
Query the set output current slope
LISTO500:25, 6
Set the times of repetitions of LIST to be 25 and LIST sets 6 dynamic values
LIST0500?
Query the times of repetitions of LIST and the number of
dynamic values
LISTOS02: 25 .6, 2 .S, 6 .5, 5 .8
Set the second dynamic value of LIST: voltage to be 25.6V, current 2.5A, slope 6.5V/100uS and time 5.8sQuery the voltage,
current, slope and time of the second dynamic value of LIST
LIST0502?
Query the voltage, current, slope and time of the second dynamic value of LIST
EXIT05:
EXIT1: 0 turn off the external trigger, EXIT1:1 turn on the external trigger
EXIT05?
Query the status of the external trigger
COMP05:
COMP1: 0 turn off the external compensation, COMP1:1 turn on the external compensation
COMP05?
Query the status of the external compensation
LOCK05:
LOCK:O unlock the buttons, LOCK:11ock the buttons
VASTEP05:1, 30, 0 .1, 1
Starting voltage 1 V, ending voltage 30V, each step 0.1V and the interval 1s
VASTOP05
Voltage stops automatically
VSTEP05:1
Set the step voltage 1V
VUP05
The step voltage set by the voltage increase
VDOWN05
The step voltage set by the voltage decrease
IASTEP05:1, 3, 0 .1, 1
Staring current 1A, ending current 3A, each step 0.1A and interval 1s
IASTOP05
Current stops automatically
Newark.com/multicomp-pro