Getting Started Guide

GPIO is a general purpose I/O interface for control integration of an AHM, Avantis or dLive system and third party hardware. It offers 8 opto-coupled inputs and 8 relay outputs on Phoenix connectors, in addition to two +10V DC outputs.

Up to 8 GPIO modules can be connected to an AHM, Avantis or dLive system via Cat cable, directly or via a network switch. GPIO functions are programmed using the AHM System Manager software, dLive Surface / Director software or Avantis mixer / Director software and can be configured for a number of install and broadcast applications, including EVAC (alarm / system mute), broadcast (on air lights, fader start logic) and theatre automation (curtains, lights).

information GPIO requires dLive firmware V1.6 or higher.

Application example

Application example

Outputs deliver DC for indicator LEDs on control panel, and switch closure for screen, projector and lighting controller.

Layout and connections

Layout and connections

  1. DC input - The unit can be powered by the supplied AC/DC adapter or alternatively via Cat5 cable when connected to a PoE source.

information Use only the power supply provided with the product (ENG Electric 6A-161WP12, A&H part code AM10314). The use of a different power supply can cause electrical or fire hazards.

  1. Network Reset - Resets Network settings to the default IP address 192.168.1.75 with subnet 255.255.255.0. Hold down the recessed switch whilst powering up the unit to reset.
  2. Network socket - PoE IEEE 802.3af-2003 compliant.
  3. Status LEDs – Light to confirm Power, physical connection (Lnk) and network activity (Act).
  4. Inputs – 8x opto-coupled inputs, switching to ground.
  5. Outputs – 8x relay outputs and 2x 10V DC outputs. All relay outputs are normally open by default. Output 1 can be configured to be normally closed as indicated here:

Cut solder link LK11 on the internal PCB.
Solder link LK10.

Installation

GPIO can be used free standing or up to two units can be installed in a 1U rack space using our optional rack ear kit FULLU-RK19 which can be ordered from your A&H dealer.
STP Cat5 or higher cables are required, with a maximum cable length of 100m per connection.

Specifications

Relay Output Max Voltage 24V
Relay Output Max Current 400mA
External Power Output +10VDC / 500mA max
Operating Temperature Range 0°C to 35°C (32°F to 95°F)
Power Requirement 12V DC via external PSU, 1A max
or PoE (IEEE 802.3af-2003), 0.9A max
Dimensions and Weights
W x D x H x Weight 171 x 203 x 43 mm (6.75" x 8" x 1.7") x 1.2kg (2.7lbs)
Boxed 360 x 306 x 88 mm (14.25" x 12" x 3.5") x 3kg (6.6lbs)

Register your product with Allen & Heath online at: http://www.allen-heath.com/support/register-product/

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download ALLEN & HEATH GPIO - General Purpose Input/Output Manual

Advertisement

Need help?

Need help?

Do you have a question about the GPIO and is the answer not in the manual?

Questions and answers

Table of Contents