Download Print this page

Advertisement

Quick Links

MODEL
Fuel Type
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size -Altitude
0-4500 ft
Minimum Input (0-2000 ft.)
Minimum Input (0-4500 ft.)
Maximum Input (0-2000 ft.)
Maximum Input (2000-
4500 ft.)
Vent Sizing
Approved for sale in the U.S.A only. This appliance does not have a 7 day timer which is required for any appliance sold in Canada.
Minimum Fireplace Dimensions
B
E
The minimum fireplace clearances and dimensions for the Regency
gas insert are shown in the following diagrams:
B
S
E
Q
D
Q
A
B
E
A
Q
A
O
O
I
K
J
O
Regency
Gi29LU-NG
Natural Gas
5" W.C. (1.25 kPa)
3.8" W.C. (0.94 kPa)
1.1" W.C. (0.27 kPa)
#38 DMS (0-2000 ft.)
#39 DMS (2000 - 4500
ft.)
17,000 Btu/h (4.98 kW)
16,500 Btu/h (4.83 kW)
31,500 Btu/h (9.22 kW)
30,500 Btu/h (8.93 kW)
3" (76 mm) x 3" (76 mm)
Co-linear (Standard)
T
T
H
R
H
R
G
B
S
E
F
T
G
F
D
H
Q
P
R
P
A
G
N
M
F
N
P
L
O
N
M
Gi29LU Gas Insert
®
Gi29LU-LP
Propane
11" W.C. (2.74 kPa)
10.5" W.C. (2.62 kPa)
2.9" W.C. (0.72 kPa)
# 52 DMS
17,000 Btu/h (4.98 kW)
31,500 Btu/h (9.22 kW)
3" (76 mm) x 3" (76mm)
Co-linear (Standard)
Letter
A
Width
B
Outerbox Width
C
Outerbox Height
D
Outerbox Depth
E
Outerbox Rear Width
F
Front to Top Taper
T
G
Front to Side Taper
H
Rear to Side Taper
H
I
Gas Inlet Height
R
J
Gas Inlet Rear Depth
C
K
Gas Inlet Front Depth
C
L
Electrical Access Height
G
L
M
Electrical Access Rear Depth
N
F
Electrical Access Front Depth
L
O
Glass Viewing Area Width
M
P
Glass Viewing Area Height
Q
Front to Intake
P
R
Front to Exhaust
C
S
Intake Diameter
T
Exhaust Diameter
N
M
Description
Dimensions
(inches)
29-3/4"
28-5/16"
20-1/4"
17-7/8"
3-13/16"
14-1/16"
12-7/16"
10-3/8"
24-1/8"
15-1/16"
C
L
Dimensions
(mm)
756 mm
719 mm
514 mm
454 mm
20"
508 mm
8-3/8"
213 mm
97 mm
357 mm
1-1/4"
32mm
5-1/2"
140 mm
316 mm
1-1/8"
29 mm
7-1/2"
191 mm
264 mm
613 mm
15"
381 mm
383 mm
14"
356 mm
3"
76 mm
3"
76 mm
Gi29LU Gas Insert |
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Gi29LU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency Gi29LU

  • Page 1 Co-linear (Standard) Approved for sale in the U.S.A only. This appliance does not have a 7 day timer which is required for any appliance sold in Canada. Minimum Fireplace Dimensions The minimum fireplace clearances and dimensions for the Regency Letter Description...
  • Page 2 (860 mm - 1445 (581 mm - 1118 mm) 4-Sided Custom Backing Plate 33-7/8" - 69" 25-1/8" - 45" 1/8" (3 mm) 2-1/8" minimum (54 mm min.) (860 mm - 1753 (638 mm - 1143 mm) | Gi29LU Gas Insert...
  • Page 3: Minimum Clearances To Combustibles

    • *An optional 2-1/2" (64 mm) mantel deflector reduces the mantel height to 13" (330 mm) from top of the unit @ 1" (25 mm) depth. • (J): ***Measured from the inside edge of the faceplate/doors - reference only: 27-1/4'' (692 mm) Gi29LU Gas Insert |...
  • Page 4 19-3/4" (451 mm) to base of unit • Although this appliance passes safety certification, the hearth in front of the fireplace becomes very hot when the fireplace heats. Do not use the hearth as a seat or shelf. | Gi29LU Gas Insert...
  • Page 5 The noncombustible mantel, when installed at a lower overall height, may not be lower than 6" (152 mm) from the top of the fireplace opening. • All material used must be non-combustible. Gi29LU Gas Insert |...
  • Page 6 Finishing Trim w/ Backing Plate 30-7/8" (784 mm) 21-7/16" (545 mm) 17-7/8" (454 mm) 20" (508 mm) 3-7/8" (98 mm) 4-Sided Finishing Trim 30" (762 mm) 21-5/16" (541 mm) 18" (457 mm) 20" (508 mm) 3-15/16" (100 mm) | Gi29LU Gas Insert...
  • Page 7 21-1/2" min. (546 mm) ING OVER MING E - Minimum Total Width 46-1/4'' (1175 mm) F - Minimum Total Height 41-3/4'' (1060 mm) Diagram 1 Combustible Facing Over Combustible Framing Non-Combustible Facing Over Non-Combustible Framing Existing Masonry Fireplace Gi29LU Gas Insert |...
  • Page 8: Gas Connection

    & flue collar at the appliance with a minimum of three self-tapping screws. Use Mil-Pac sealant to seal the pipes. The air intake pipe must be attached to the inlet air collar of the termination Gas & Electrical Connections | Gi29LU Gas Insert...
  • Page 9 3" Co-linear Adaptor with flashing In areas with consistently high winds, we recommend using the Simpson Dura-Vent System (46DVA-GK adaptor and 46DVA-VCH high-wind cap). The air intake pipe must be attached to the inlet air collar of the termination cap. Gi29LU Gas Insert |...
  • Page 10 Vertical Venting/Restrictor Settings for NG and LP Setting #3 Setting #4 4-1/2" open 2" open Setting #2 2-1/2" open Setting #1 Setting #2 1" open 2-1/2" open | Gi29LU Gas Insert...
  • Page 11 It cannot be used for burning wood or solid fuels unless all original C - Max. Horizontal 18" (457 mm) parts are replaced and the fireplace re-approved by the authority having jurisdiction. Gi29LU Gas Insert |...

This manual is also suitable for:

Gi29lu-ngGi29lu-lp