Service Manual For Built-in gas hob Model list 60G40ME097-GFT Warnings: This service manual is not available to the general users, but only applies to professional technicians with relevant qualifications. Any incorrect maintenance may result in other dangers! The power and gas supply must be cut off before maintenance! ...
6.Reassembly and Disassembly…………………………………………………………….9 6.1. Safty precautions…………………………………………………………………..9 6.2. Tools……………………………………………………………………………..9 6.3. Reassembly………………………………………………………………………..9 6.3.1. Reassemble of the Ignition Pin……………………………………………...9 6.3.2. Reassemble of the Thermocouple…………………………………………..10 6.3.3. Reassemble of the Gas Pipe………………………………………………...10 6.3.4 Reassemble of Gas Valves…………………………………………………...10 6.4.Disassembly………………………………………………………….……….……11 6.4.1. Disassemble of the Top Plate…………………………………….….……..….11 6.4.2. Disassemble of the Thermocouple……………………………….…..……….12 6.4.3.
1.1. Safety Precaution 1. Do not modify this appliance. 2. This appliance should be serviced by an authorized person. 3. All repairs should be done in accordance with the procedures described in this manual. 4. Before you begin, turn off the gas and electricity supply to the appliance. 5.
60G40ME097-GFT Model W (mm) D (mm) H (mm ) 60G40ME097-GFT Note: Dimensions for reference only 3. Description of the appliance 3.1. Features 1. Top-plate 2. Right pan support 3. Knob 4. Auxiliary burner 5. Left pan support 6. Triple-crown burner...
5.Installation This appliance is to be built into a kitchen unit or worktop of right size,providing the following minimum distances are allowed; – The edge of the appliance must be a minimum distance of 55mm from a rear wall. – A minimum distance of 20m must be left between the side edges of the appliance and any adjacent cabinets or walls.
–Gas pipe or connector shouldn't be bent or blocked by any other appliances – You must conduct a gas leakage test after installation over gas connection and gas pipe. – An oven must have forced ventilation to install a hob above it. –...
6.3.2 Reassemble of the Thermocouple Step 1. Insert thermocouple into the the relevant hole of the bottom cup from bottom to top. Step 2. Adjust position of the thermocouple in the hole of the bottom cup. Step 3. screw up the nut to fix the thermocouple. 6.3.3 Reassemble of the Gas Pipe Step 1.Insert the head of the gas pipe into installation parts of the bottom cup or the valve Step 2.Screw up the nut of the joint with spanner...
Triple Crown (Rapid) Semi-Rapid Semi-Rapid G20/13 Black-- Blue Black-- Black-- Green Black-- Yellow Black-- Yellow G20/20 Red-- Blue Red-- Red-- Green Yellow Yellow G30/29 Non-- Blue Green Yellow Yellow 6.4. Disassembly 6.4.1 Disassemble the Top Plate Step 1:Remove parts on the Top Plate a.
60G40ME097-SFT 60G40ME097-GFT 75G50ME005-SFT 75G50ME060-GFT 6.4.2 Disassemble the Thermocouple Step 1: Unscrew the nut out. Step 2: Pull the silver terminal of Thermocouple Step 3: When reassembling, replace parts correctly 6.4.3 Disassemble of the Ignition Pin Step 1: Pull the washer and take off ignition pin...
6.4.4 Disassemble of the Microswitch Harness Step 1: Before you disassemble the harness, take off the plastic e – ring. Step 2: When you take off the micro switch harness , please be careful not to break the hook. Step 3: When you reassemble the harness, replace it correctly. Step 4: Detach the wire from the power cord assembly harness.
6.4.7 Disassemble of the Power Cord Assembly Step 1 . Detach the wire from the Microswitch Harness. Step 2 . Hold housing of the wire by hand and pull it out of the igniter. Step 3. For power cord grounding, you must use grounding screw attached with washer. Step 4 .
6.4. 10 Disasmble of the Gas Connection a. When you disassemble/assemble gas connection, use 2 spanners. One for fixing gas connection elbow, the other for tightening gas hose. b. Tighten enough to prevent gas leakage. c. Once you’re done, conduct leakage test Check Point after assemble a.
7.3 Maintenance and test Air leakage test Tool: Air leakage device, soapy water 1. Professional repair procedures a) Connect product to the air leakage device and set the test pressure at 15kPa; b) The plug valve shall be kept closed and the gas pipelines may be tested its leakage through air leakage device;...
Steps for operation: a) Disassemble with a wrench the gas-type fittings from main gas tube. b) Lock tightly a replaceable gas-type fitting onto the main gas tube. 8.3 Adjustment of minimum level of the flame A. Turn the taps down to minimum B.