Munters Italy S.p.A. reserves the right to effect modifications to the apparatus in accordance with technical and legal developments and to make alterations to specifications, quantities, etc., for production or other reasons, subsequent to publication.
EM50 1.4 Data for Fan Eco Design Directive Table 1 Product information requirements* (according to ANNEX I - 3.2 of regulation) Fan description* EM50 1.5hp 3ph 50Hz OS 35.4 static 40.3 1669 30519 69.6 EM50 1.0hp 3ph 50Hz OS 33.9 static 40.1...
Page 12
EM50 - 1.0hp 67.6 EM50 - 1.5hp 70.4 EM50 2.5hp – E-Line 70.3 Measurements performed according to standard EN ISO 3744:2010 WARNING The user and the employer must comply with current national law in terms of protection against daily personal exposure of operators to noise, by providing the use of personal protective equipment (earmuffs, earplugs, etc.) if necessary,...
Consequently one of the following components: alternatives should be used: • fan housing in Munters Protect coated • trolley: when loading the fan on the steel without welding spots; trolley make sure fan shutter is positioned •...
The user is responsible for preparing an coating made of an alloy of Zinc, area suitable for installation of the Aluminum and Magnesium (‘Munters equipment and complying with the Protect’), classified as ZM120 (equivalent requirements laid down by European to 9 µm of coating thickness on each side...
Page 22
0-10Vdc voltage is less than the minimum voltage (for example: 0.5V for Saturn 5, EM50, Saturn Breeze), then the motor will stop, obviously in the opposite case (voltage 0-10Vdc greater than the minimum voltage) the impeller will start to rotate. In order to control the fan with just 2 wires, in addition to the setting on the App (Enable under stop = 0), it is also necessary to connect pins 7 and 8 together.
Page 24
Reset the alarm and trying the movement again or turning the device off and on again after waiting Loss of synchronism (lock) at least one minute. Check with Munters that the minimum speed is not too low (from FF to FOC) or that the acceleration at the start is not too high (boost).
Page 25
Check that the Id [A] (deflux current) is not too high and check with the help of an electrician that the Voltage supply is into the working range. Switch the supply of and check also that the fan can rotate easily and that there are not any obstacles. In case contact Munters customer service.