Download Print this page

F&F PR-602 Quick Start Manual

Priority relay

Advertisement

Quick Links

PR-602
Priority relay
Do not dispose of this device in the trash along with other waste!
According to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collec� on, as well as to store the occasion of
the purchase of new equipment (in accordance with the principle of old-for-new, regard-
less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the
environment and human health.
Purpose
Priority relays are used when there are at least 2 high-power
loads connected to the circuit, which can operate independen-
tly, and their simultaneous operation would result in tripping of
the current protections.
Functioning
The potentiometer is used to set the value of current con-
sumption in the priority circuit, above which the relay switches
off the non-priority circuit. A decrease of current consumption
in the priority circuit below the set threshold value will automa-
tically switch on the non-priority circuit. In the event that the
priority load is already switched on, the relay will prevent the
non-priority load from being switched on.
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
- 1 -

Advertisement

loading
Need help?

Need help?

Do you have a question about the PR-602 and is the answer not in the manual?

Questions and answers

Summary of Contents for F&F PR-602

  • Page 1 Konstantynowska 79/81, 95-200 Pabianice, POLAND phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71 www.fif.com.pl; e-mail: biuro@fif.com.pl PR-602 Priority relay Do not dispose of this device in the trash along with other waste! According to the Law on Waste, electro coming from households free of charge and can give any amount to up to that end point of collec�...
  • Page 2 Mounting 1. Disconnect the power supply. 2. Fasten the priority relay to the floor with 2 screws. 3. Connect the power supply of the relay to terminals 1-3 as shown in the diagram. 4. Connect the power supply of the priority receiver to terminal 2 (L’).
  • Page 3 Technical data power supply 195÷253 V AC maximum non-priority receivers current (AC-1)* 16 A maximum priority receivers current (AC-1) 15 A contact separated 1×NO switching current 2÷15 A switching delay 0.1 s return hysteresis return delay 0.1 s power consumption 0.4 W working temperature -25÷50°C...
  • Page 4 Warranty The F&F products are covered by a warranty of the 24 months from the date of purchase. Effective only with proof of purchase. Contact your dealer or directly with us. CE declaration F&F Filipowski L.P. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE.