DOOR REvERSAL (OPTIONAL)

The following instructions are for models with a round-shaped
door. For models with a square shaped door, an additional kit is
needed. Please contact your retailer, or see the For Assistance
or Service page in your Use and Care Guide.
Tools needed:
Min. 8" long Torx
T25
®
screwdriver
1.
Remove door from dryer
Using a Torx
T25 screwdriver, remove the 4 screws securing
®
the door hinge to the dryer and lift up and out to remove the
door. Place the door on a soft towel or other non-scratch
surface. Reinstall the 4 screws in the holes.
† ® TORX is a registered trademark of Acument Intellectual Properties, LLC.
#2 Phillips screwdriver
2.
move the door strike
Using a Torx
T25 screwdriver, remove the 2 screws securing
®†
the door strike to the door frame of the dryer. Rotate the
strike 180° and attach to the opposite side of dryer door
frame, as shown.
3.
Remove inner door from outer door
Position the door with the inside of the door facing up.
Using a Phillips screwdriver, remove the 10 screws securing
the inner door to the outer door. Lift off the inner door and
set aside.