Maytag MED6400T Product Dimensions

Dimensions
Hide thumbs Also See for MED6400T:

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
MED6300T
MED6400T
Electrical: A 3 or 4 wire, single phase, 120/240
volt, 60 Hz, AC only electrical supply (or 3 or 4
wire, 120/208 volt electrical supply, if specified on
the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended.
Connect to an individual branch circuit. Do not
have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the
outside. 4" (10.2 cm) diameter vent is required.
Heavy metal exhaust vent and clamps must be
used. Do Not use plastic or metal foil vent.
Exhaust hood must be at least 12" (30.5 cm) from
the ground or any object that may be in the path of
the exhaust.
EXHAUST VENTING
Number of
Type of
Box or
90° turns
vent
Louvered
or elbows
hoods
0
Rigid metal
64 ft (20 m)
Flexible metal
36 ft (11 m)
1
Rigid metal
54 ft (16.5 m)
Flexible metal
31 ft (9.4 m)
2
Rigid metal
44 ft (13.4 m)
Flexible metal
27 ft (8.2 m)
3
Rigid metal
35 ft (10.7 m)
Flexible metal
25 ft (7.6 m)
4
Rigid metal
27 ft (8.2 m)
Flexible metal
23 ft (7 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Electric Dryer

OVERALL DIMENSIONS
43½"
(110.5 cm)
*29¼"
(74.3 cm)
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent air ventilation openings
in the top and bottom are acceptable.
18"*
(45.7 cm)
1"
(2.5 cm)
Recommended hood styles
Angled
hoods
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
29 ft (8.8 m)
17 ft (5.2 m)
Select the route that will provide the straightest and most direct path
21 ft (6.4 m)
outdoors. Plan the installation to use the fewest number of elbows and turns.
15 ft (4.6 m)
Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
29"
(73.7 cm)
1"
*
1"
29"
(73.7 cm)
(2.5 cm)
(2.5 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
B
A
4"
(10.2 cm)
4"
(10.2 cm)
A . Louvered hood style
B . Box hood style
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
* Most installations require a minimum 5"
(12.7 cm) clearance behind the dryer for the
exhaust vent with elbow. See Installation
Instructions, "Venting Requirements."
22¼"
(56.5 cm)
14" max.*
*
(35.6 cm)
2
48 in.
2
(310 cm )
*
2
24 in.
(155 cm )
2
29-1/4"
5"*
(74.3 cm)
(12.7 cm)
B
Angled hood style is
acceptable.
4"
(10.2 cm)
2. ½ "
(6.4 cm)
3"*
(7.6 cm)
3"*
(7.6 cm)
C
Ref. W10088777
10-15-07