Carter-Hoffmann
Preventative Maintenance:
HotLOGIX 1-4
HL2-18
WARNING:
DO NOT perform these procedures
while the cabinet is turned on or heat-
ed. Turn off the power and wait for the
cabinet to cool to room temperature.
CAUTION:
Do not move cabinet unless door is
securely closed. Serious damage to
hinges and door may result if bumped
into tables, walls, or other equipment
when the doors are open.
Periodic Maintenance
CASTERS
Some cabinets may have caster bearings that are equipped with
Zerk grease fittings so that they may be easily lubricated with a
grease gun. Lubricate bearings at least once every six months.
HINGE MAINTENANCE
Make sure all joints remain sealed and door latches do not stick. If
necessary, use WD-40 to keep door latches from sticking. Do not
use oil.
REVERSING THE DOOR
Reversing the door takes about 30 minutes & requires two people.
1. Using a small screwdriver, pry off the hinge covers and set
aside. Removing the covers will allow access to the inside hinge
screws. Remove the three screws that hold each hinge to the
cabinet. DO NOT REMOVE THE SCREWS THAT HOLD THE
HINGES TO THE DOOR. Remove the door, taking care not to
let it fall.
2. Remove the door strike plate and screws adjacent to the door
opening on the cabinet. Reinstall door strike plate and screws
on opposite side of the cabinet.
3. Screw hinges onto opposite side of the door.
4. With the help of another person, hold door up to the cabinet and
attach with the screws removed in step one. Before tightening
the screws, be sure the door is flush, level and square. Replace
the hinge covers.
Need help?
Do you have a question about the HotLOGIX 1-4 and is the answer not in the manual?
Questions and answers