Safety Notice
The manufacturer is discharged from liability when damage
is caused by improper use or installation.
If any luminaire and/or accessory is subsequently modi-
fied, the persons responsible for the modification shall be
considered as manufacturer.
Product Information / Surge Protection
As an option, this luminaire can also be fitted with a surge
protector of Type 2-3. The technical data can be found
directly on the installed device. If the surge protector has
been triggered by an adverse event, the luminaire is auto-
matically disconnected from the mains. In that case, the
LED on the surge protector no longer lights up.
For comprehensive protection of the luminaire against
lightning and electrical surges, primary (Type 1) and
secondary (Type 2) surge arrestors must be installed into
the power supply. We recommend a combination arrestor
(Type 1+2+3), which is installed in the control cabinet.
WE-EF LIGHTING USA
Tel +1 724 742 0030
info.usa@we-ef.com
we-ef.com
The technical planner/installer is responsible for the pro-
per selection, sizing and installation of the surge protection
modules that must be provided on site. Please note the
various protection levels for Class I and II, as well as the
applicable statutory provisions regarding surge protection.
Installation and maintenance may only be performed by a
qualified electrician.
ZA600 LED_130722 / 006-1170
Technical specifications are subject to change.
© WE-EF 2022
WE-EF LIGHTING
Installation and
Maintenance Instructions for
Post Top Luminaire
ZA600 LED Serie
Need help?
Do you have a question about the ZA600 LED Series and is the answer not in the manual?
Questions and answers