Model: R718X
Wireless Ultrasonic Distance Sensor with Temperature Sensor
Wireless Ultrasonic Distance Sensor
with Temperature Sensor
R718X
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in
strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX
Technology. The specifications are subject to change without prior notice.

Advertisement

loading
Need help?

Need help?

Do you have a question about the R718X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox R718X

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    7.1 The waste bin with frame ..........................21 7.2 The waste bin without the frame but an upper cover ..................21 7.3 Plastic Bucket Test of R718X ......................... 21 7.4 Installation ............................... 22 8. Information about Battery Passivation ........................24 1.
  • Page 3: Introduction

    (for example: detect the height of garbage in the waste bin). R718X also has the temperature detection function, it can detect the temperature of the waste bin. R718X would send out the detected data through wireless network.
  • Page 4: Appearance

     Available third-party platform: Actility / ThingPark, TTN, MyDevices/Cayenne  Low power consumption and long battery life Battery Life: ⁻ Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html ⁻ At this website, users can find battery lifetime for variety models at different configurations.
  • Page 5: Set Up Instruction

    4. Set up Instruction On/Off Power on Insert batteries. (users may need a screwdriver to open) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off Press and hold the function key for 5 seconds till green indicator flashes for 20 times. (Restore to factory setting) Power off Remove Batteries.
  • Page 6: Data Report

    (1) The device report interval will be programmed based on the default firmware which may vary. (2) The interval between two reports must be the minimum time. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://cmddoc.netvoxcloud.com/cmddoc...
  • Page 7: Example Of Reportdatacmd

    Version– 1 byte –0x01——the Version of NetvoxLoRaWAN Application Command Version DeviceType– 1 byte – Device Type of Device The devicetype is listed in Netvox LoRaWAN Application Devicetype doc ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype NetvoxPayLoadData– Fixed bytes (Fixed =8bytes) Tips 1.
  • Page 8 (00): Reserved Packet 2: 0134029F01000000000000 // When the ThresholdAlarm is enabled will the packet be sent. byte (01): Version byte (34): DeviceType — R718X byte (02): ReportType byte (9F): Battery — 3.1V Threshold Alarm byte (01): Threshold Alarm — Low Distance Alarm Low Distance Alarm = 0x01 (bit0=1) –...
  • Page 9: Example Of Data Configuration

    (9Bytes,Fixed 0x00) Temperature BatteryChange DistanceChange ReadConfig MinTime MaxTime Change 0x82 (1byte (2byte ReportRsp (2bytes Unit:s) (2bytes Unit:s) (2byte Unit:0.1v) Unit:1mm) R718X 0x34 Unit:0.1℃) SetOnDistance OnDistanceThreshold Reserved 0x03 ThresholdRreq (2byte Unit:1mm) (7Bytes,Fixed 0x00) SetOnDistance Status Reserved 0x83 ThresholdRrsp (0x00_success) (8Bytes,Fixed 0x00)
  • Page 10 SetFillMax Status Reserved 0x85 DistanceRsp (0x00_success) (8Bytes,Fixed 0x00) GetFillMax Reserved 0x06 DistanceReq (9Bytes,Fixed 0x00) GetFillMax FillMaxDistance Reserved 0x86 DistanceRsp (2byte Unit:1mm) (7Bytes,Fixed 0x00) SetDeadZone DistanceReq DeadZoneDistance Reserved 0x0B ( Keep the last set (2byte Unit:1mm) (7Bytes,Fixed 0x00) value when restoring the factory setting) SetDeadZone Status...
  • Page 11 8534010000000000000000 (Configuration failed) (4) Read the total height of the container (FillMaxDistance) Downlink:0634000000000000000000 Device returns: 8634138800000000000000 (Device current parameter) Switch the Mode If the mode of the device is waste bin detection, switch it to parking detection. (5) Set FillMaxDistance to 0 Downlink:...
  • Page 12: Example Of Globalcalibratecmd

    Set Dead Zone Distance Support after data code 20211220 (include) (9) SetDeadZoneDistance Downlink: 0B3400C800000000000000 // set the device detection dead band to 200mm, 00C8 (H ) = 200 (D Device returns: 8B34000000000000000000 (10) GetDeadZoneDistance, and check whether it is set successfully. Downlink:...
  • Page 13 (3) Set the temperature calibration: If the temperature the R718X detects is 26° and the actual temperature is 27°, it means the calibration we want to make is +1°. SensorType =0x01 ,Channel 2= 0x01, Multiplier = 000A, Divisor = 0000, DeltValue=0001 Downlink:010101000A000000010000...
  • Page 14: Example Of Alarmthresholdcmd

    5.4 Example of AlarmThresholdCmd FPort: 0x10 (port = 16, Dec) CmdID CmdDescriptor Payload(10Bytes) (1Byte) SensorType(1Byte) SensorHighThreshold SensorLowThreshold 0x00_ Disable ALL Channel (4Bytes) (4Bytes) SetSensorAlarm SensorthresholdSet 0x01 (1Byte) Temperature, Unit:0.1°C Temperature, Unit:0.1°C ThresholdReq 0x01_Temperature Distance, Unit:1mm 0x00_Channel 1 Distance, Unit:1mm 0x2F_ Distance FillLevel, Unit:1% FillLevel, Unit:1% 0x30_ FillLevel...
  • Page 15 (1) Configure distance high alarm = 5000mm, low alarm =4000mm Downlink: 01002F0000138800000FA0 // 1388(Hex)=5000(DEC) // FA0(Hex)=4000(DEC) Response: 8100000000000000000000 (Configuration success) (2) GetSensorAlarmThresholdReq Downlink: 02002F0000000000000000 Response: 82002F0000138800000FA0 (Configuration success) (3) Clear all SensorThreshold (Sensor type=0x00) Downlink: 0100000000000000000000 Response: 8100000000000000000000...
  • Page 16: Lorawanrejoin

    5.5 LoRaWANRejoin Check if the device is still in the network. If the device is disconnected, it will automatically rejoin back to the network. FPort: 0x20 (port = 32, Dec) CmdID CmdDescriptor Payload(5Bytes) (1Byte) SetNetvoxLoRaWAN RejoinCheckPeriod RejoinThreshold 0x01 RejoinReq (4Bytes,Unit:1s) (1Byte) SetNetvoxLoRaWAN Status...
  • Page 17: Example For Mintime/Maxtime Logic

    5.6 Example for MinTime/MaxTime logic Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime Sleeping(MinTime) Sleeping(MinTime) Wake up and collects data Wakes up and collects data Wakes up and collects data REPORTS 3.6V REPORTS 3.6V REPORTS 3.6V Note: MaxTime=MinTime.
  • Page 18 1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data. 2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the device reports according to MinTime interval.
  • Page 19: Application Scenario

    6. Application scenario In the use case of detecting the garbage in waste bin, the device should be installed on the top of the waste bin. After the device is installed and powered, turn on the device and it will detect the distance between the device and the garbage as well as the percentage of the garbage in the waste bin.
  • Page 20 The calculation method of water level percentage of deadzonedeistance can be set FillLevel = ((H - D) / H-d) * 100% Illustration 3. If the R718X is installed as the following way, then the measured distance needs to add the height of the device itself which is 28mm. Note: (1) The default value of OnDistanceThreshold is 500mm, and the default value of FillMaxDistance is 2000mm.
  • Page 21: Installation

    User should find and make sure the installation location that is parallel to the bottom of the waste bin. Namely, the detecting direction is perpendicular to the bottom of the waste bin. Horizontal Plane 7.3 Plastic Bucket Test of R718X Probe position The probe offset center point 7cm The probe offset center point 5 cm The probe is offset to the right 5.5 cm...
  • Page 22: Installation

    7.4 Installation Use screws and locking nuts to fix the device, as the figure for reference. M4 Locking Nut M4 Gasket M4*20 Machine Screw 1. After finding the installation position, use the tool to drill 2 holes in the upper cover. M4 screws can be inserted into the hole.
  • Page 23 Container ✖ R718X 2.Please do not disassemble the device unless it is required to replace the batteries. Do not touch the waterproof gasket, LED indicator light, function keys when replacing the batteries. Please use suitable screwdriver to tighten the screws.
  • Page 24: Information About Battery Passivation

    8. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
  • Page 25: Important Maintenance Instruction

    9. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.