and that static charge may be generated by the friction of the particles against the container. For appropriate
measures, see IEC/TS 60079-32-1.
When the container is to be emptied, the two fasteners must be carefully released, one at a time, to prevent dust
from swirling up unnecessarily. When the machine's container has been lowered, turn on the separator again so
that any stuck particles are sucked into the filter cyclone.
For DC 1800 H EX, release the fasteners and lift the upper part of the machine. The container can now be removed
from the machine.
Carefully remove the filled sack from the edge of the container and immediately seal it tightly.
Fit a new plastic sack and place the opening carefully back over the edge of the container. Make sure that no
creases are formed and that the sack is not damaged. Then carefully install the tray under the separator and fasten
the two hooks, turn off the machine and once more secure the tray on the machine, make sure that the fastening
hooks are located properly and check for leakage.
CAUTION
The strap of the fasteners must have good contact with the plate on the upper part. The black
arrow markings must be aligned so that they point at each other.