Filter cleaning
The filters should be cleaned when the manometer is in the red field.
1.
Leave the machine switched on and close the damper on the cyclone inlet.
2.
Adjust the filter cleaning button.
3.
Wait for 5-10 pulses.
4.
Switch off the machine.
5.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
6.
Switch on the machine.
7.
Check that the pressure gauge is on green. If not - repeat the procedure. If the meter is on red even after the
repetition, the fine filter needs to be replaced.
Emptying
The container under the cyclone should be emptied when it is filled to a maximum of 2/3.
Be careful when releasing the fasteners – they can open with great force – especially when the material is heavy.
Be aware that emptying the container may pose a risk of explosion, i.e. that an explosive atmosphere may occur
DC Tromb Turbo EX
40