Introduction
IES-3000-LA Series are managed redundant ring Ethernet switch which is
specifically designed for the toughest. IES-3000-LA Series support wide
operating temperature from -40° C to 75° C which can fulfill most of the
requirement of operation environment. Therefore, the IES-3000-LA Series
switch is one of the most reliable choices for highly-managed Ethernet
application.
Package Contents
The device is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Contents
Pictures
Number
Switch
CD Card
Console Cable
QIG
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Safety & Warnings
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Mechanical Loading: Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
Q I G
IES-3000-LA Series
IES-3000-LA Series
G
uide
Dimension
X 1
X 1
X 1
X 1
Warning [AVERTISSEMENT]
!
Take into consideration the following guidelines before wiring the device.
[Tenez compte des directrices suivantes avant de câbler l'appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG. Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d'entrée doit être supérieure à 105 °C]
3. Use Copper Conductors Only.
[Utilisez uniquement des conducteurs en cuivre.]
* Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the device and label.
* Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour nettoyer l'appareil et son étiquette.
* Do not block air ventilation holes.
* Ne bouchez pas les orifices de ventilation.
* If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may
be impaired."
* Si l'appareil est utilise d'une maniere non specifiee par le fabricant, la protection qu'il apporte peut se voir diminuee.
* Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed 75 degree C
* doit être monté dans le panneau de commande industriel et la température ambiante ne doit pas dépasser 75 degrés C.
Unit =mm (Tolerance ±0.5mm)
107.30
54.30
IES-3082GP-LA
125.00
76.00
IES-3164GP-LA
PRINTED ON RECYCLED PAPER
Industrial Managed Ethernet Switch
Installation
DIN-rail Installation
STEP 1—Insert the upper lip of the
DIN-rail kit into the mounting rail.
S T E P 2 — P r e s s t h e S w i t c h t o w a r d s
the mounting rail until it snaps into
place.
DIN-rail Removal
STEP 1—Pull down the latch on
the DIN-rail kit with a screwdriver.
STEP2 —Slightly pull the
switch forward and lift up to
remove it from the mounting
Step2
rail.
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3,4,5,5e UTP cables to connect to any other network devices
switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
Cable
Type
10BASE-T
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
10/100 Base-T(X) RJ-45 Port
Pin Number
Pin Number
Assignments
1
1
TD+
2
2
TD-
3
3
RD+
4
4
Not used
5
5
Not used
6
6
RD-
7
7
Not used
8
8
Not used
Note: "+" and "-" signs represent the polarity of the wires that make up each wire pair.
Quick Installation Guide
Version 1.0
Step1
DIN rail
Step2
DIN rail
Step1
(PCs, servers,
Max. Length
Connector
RJ-45
RJ-45
MDI port
MDI-X port
TD+(transmit)
RD+(receive)
TD-(transmit)
RD-(receive)
RD+(receive)
TD+(transmit)
Not used
Not used
Not used
Not used
RD-(receive)
TD-(transmit)
Not used
Not used
Not used
Not used