  • Page 1 Assembly Instructions Seminar Tables June 2020...
  • Page 2 125 PSF. Note: If any other flooring types exist that are Note: KI is not responisble not shown, please provide you KI contact for how flooring is secured. with the detailed floor specifications. See applied loads.
  • Page 3 • #2 and #3 Phillips head Note: Warranty null and void if • ” Hilti KH-EZ x 2 ” screwdriver bits KI product is installed on flooring • Max torque: 18 ft/lbs • Tape measure not meeting minimum structural •...
  • Page 4 Failure to assemble properly, or to secure parts may result in assembly failure and personal injury. Note: When installing Seminar Tables equipped with the power & data module or undersurface power and data extra care must be taken to hold very...
  • Page 5 Position the proper engagement of flange covers base on the floor at the center mark later. After all bases are positioned Seminar Select Base Seminar Basic Base and adjusted with shims, securely where the base will be installed.
  • Page 6 Seminar Tables - Bases & Tops Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 7 (Detail C or Detail D). Note: For installation of Seminar Tables with undersurface power and data, skip now to step 23, page 14. For installations without PowerUp, or undersurface power &...
  • Page 8 Figure 6 Seminar Tables with PowerUp Note: When installing the 12. Refer to the space-planning layout 13. On either the right- or left-hand it is up against the support arm.
  • Page 9 Seminar Tables with PowerUp Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 10 Note: Power infeeds for the correct installation of components. length of the conduit by verifying screws at the pre-drilled holes Seminar Tables with the PowerUp that both ends of the conduit will (Figure 8). Torque screws to system may include one or both of 16.
  • Page 11 Seminar Tables with PowerUp Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 12 Failure to assemble properly, or to secure parts may result in assembly failure and personal injury. Seminar Tables with PowerUp (cont.) 19. The data wiring (not provided) may be installed at this time. Referring to the space-planning layout, locate the data wire infeed locations.
  • Page 13 Seminar Tables with PowerUp Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 14 Seminar Tables, the power & where the power & data trough location of the support arm as from guide marks to support arm data troughs must be properly is to be positioned between.
  • Page 15 Seminar Tables with Undersurface Power & Data Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 16 (exposed 8-wire end) (connector end) power infeed (right) (run from below floor level) Figure 14 Seminar Tables with Undersurface Power & Data (cont.) Note: All table connections (joint that mounts to the underside of floor level (Figures 14, 15 or 16).
  • Page 17 Seminar Tables with Undersurface Power & Data Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 18 Failure to assemble properly, or to secure parts may result in assembly failure and personal injury. Seminar Tables with Undersurface Power & Data (cont.) 31. The data wiring (not provided) may be installed at this time.
  • Page 19 Seminar Tables with Undersurface Power & Data Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 20 Seminar Tables - Power Infeed Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 21 Seminar Tables - Modesty Panels Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 22 Seminar Tables Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 23 Seminar Tables - Modesty Panels Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 24 Seminar Tables - Modesty Panels Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 25 Seminar Tables - Modesty Panels Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 26 Seminar Tables - 8-Wire Diagram Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 27 Seminar Tables Assembly Instructions...