Functional Symbols
DGMPC-5- AB *-30
P
T
B
A
1
1
P
T
B
A
Operating Data
Basic Characteristics
Maximum flow
Maximum operating pressure
Leakage @ 50°C (120°F) Poppet @ 35 bar (500 psi)
Standard models
"D" models
Piston @315 bar (4500 psi)
Operating temperature
Weights
Performance Data
DGMPC Pressure Drop
The curves below show pressure drop through each
functional flow path in the valve. The total insertion loss for
the valve must be calculated by summing the losses through
the four applicable flow paths.
Model Type
DGMPC-5-(D)-AB*-30
DGMPC-5-(D)-BA*-30
DGMPC-5-(D)-AB*-(D)-BA*-30
• Flow toward actuator without check – single check only
Flow from actuator without check – single check only
Use K, M, or N cracking pressure curve as applicable
30
DGMPC-5- BA *-30
P
T
B
P
T
B
Curve Number
P
T
A
1
2
-
5
1
2
• 3
-
4
1
2
-
5
DGMPC-5- AB *- BA *-30
P
T
A
1
1
P
T
A
120 l/min (32 USgpm)
315 bar (4500 psi)
0.3 ml/min.
1.0 ml/min.
20°C to 50 °C (70 to 120° F)
20°C to 50°C (70° to 120°F)
2,9 kg (6.4 lbs)
B
• 3
-
-
4
-
-
5
-
5
B
A
1
1
B
A
Flow USgpm
5
10
15
20
25
24
22
N
20
18
16
14
12
10
8
4
6
M
5
3
4
K
2
2
1
0
20
40
60
80 100 120
Flow l/mi n
30
300
250
200
150
100
50
0