8. Troubleshooting Guide
Issues Causes
The
1.The probe is
probe
placed in a
reading
area with
is
poor
incor-
temperature
rect.
circulation.
2.The probe is
damaged.
Heating
1. Incorrect
output
settings.
will not
2. Incompati-
turn on.
ble heater.
3. Output
malfunction.
Cooling
1. Incorrect
output
settings.
will not
2. Incompati-
turn on.
ble cooler.
3. Output
malfunction.
Solutions
1. Adjust the position of the probe.
2. If the probe was used in liquids, dry it
using a hairdryer and then test it at room
temperature.
3. Check if the probe is intact.
4. If the deviation is small, please use the
CA function to calibrate.
1. Verify that the settings are correct.
2. The heater power is within the range
of 100-240V, 10A. The heater can
automatically turn on when plugged in.
The heater does not have a built-in
temperature control, or the built-in
temperature control does not affect the
ITC-308 control.
3. There is no problem with 1&2,please:
· Unplug the controller.
· Press and hold the "SET" button.
· Plug the controller to power on, then
release the "SET" button
· Quickly press the " " button ( do not
press the "
" button). The "HEATING"
indicator and output should activate.
If the heater still does not work, please
contact customer service.
1. Verify that the settings are correct.
2. The cooler power is within the range of
100-240V, 10A. The cooler can
automatically turn on after power is
connected. The cooler does not have a
built-in temperature control, or the built-in
temperature control does not affect the
ITC-308 control.
3. There is no problem with 1&2,
please:
· Unplug the controller.
· Press and hold the "SET" button.
· Plug the controller to power on, then
release the "SET" button
· Quickly press the "
press the " " button). The "COOLING"
indicator and output should activate.
If the cooler still does not work, please
contact customer service.
8
" button ( do not
Need help?
Do you have a question about the ITC-308 and is the answer not in the manual?
Questions and answers
itc 308 does not get power
@Romi Khosla
The Inkbird ITC-308 may not be receiving power due to the following reasons:
1. The power socket is not supplying power. Try plugging the device into a different outlet.
2. The connected heater or cooler exceeds the power limit (100-240V, 10A).
3. A device malfunction. If the issue persists, contact customer service.
This answer is automatically generated