Download Print this page

Advertisement

Quick Links

Revision 3
05/06/23
Micro Meter
Micro Meter Operating Manual & Parts List P

Advertisement

loading
Need help?

Need help?

Do you have a question about the Micro Meter and is the answer not in the manual?

Questions and answers

Summary of Contents for Stocks AG Micro Meter

  • Page 1 Revision 3 05/06/23 Micro Meter Micro Meter Operating Manual & Parts List P...
  • Page 2: Table Of Contents

    Product Calibration 11.6 Calibration Catch and Weigh Test 12.0 i-CON Controls 12.1 i-CON Control System 12.2 Wiring diagram 12.3 Electrical Connections 12.4 i-CON Instrument Functions 12.5 Precision Farming Software 12.6 i-CON Calibration Micro Meter Operating Manual & Parts List P2...
  • Page 3 Calibration Catch and Weigh Test 15.0 Micro Meter Add-On Parts Drawing 15.1 Micro Meter Add-On Parts List 15.2 Micro Meter Add-On Parts List Cont 16.0 Micro Meter Combi Parts Drawing 16.1 Micro Meter Combi Parts List Micro Meter Operating Manual & Parts List P3...
  • Page 4: Declaration Of Conformity

    Micro Meter Operating Manual & Parts List P4...
  • Page 5: Ukca. Declaration Of Conformity

    Micro Meter Operating Manual & Parts List P5...
  • Page 6: General Information

    Add-On or Combi Units must be used in conjunction with a Micro Meter Vari-Speed or Micro Meter i-CON Drive Unit. One Add-On Unit can give up to 1.5m working width for an even broadcast effect or to a wider width if band sowing.
  • Page 7: Machine Identification

    Please see our conditions of sale for full details, a copy of which available upon request. Please record the machine serial number here: ……………………………… Purchase date: …………………………………………… Dealer …………………………… Micro Meter Operating Manual & Parts List P7...
  • Page 8: Safety

    If in doubt contact the vehicle manufacturer for more information. After working the machine ensure that any unused product is returned safely to its original packaging. Stocks AG Ltd. does not accept any liability for the storage and use of the material being applied.
  • Page 9: Safety Warning Decals

    Keep Clear! Maintain a safe distance from the machine when in operation. Wear the appropriate protective personal equipment. WARNING! Do Not Jet Wash This machine is not designed to withstand Jet Washing. Micro Meter Operating Manual & Parts List P9...
  • Page 10: Emergency Stop Instructions

    Ensure any product removed is put back into its original container Care to be taken not to spill any product that could contamination the environment. Empty the hopper of any remaining product - industrial vacuum recommended. Investigate and unblock as required. Micro Meter Operating Manual & Parts List P10...
  • Page 11: Pvc Waterproof Covers

    In no circumstances should a machine be used for nematicide or any other toxic material without this kit fitted. For more information please contact your local Stocks Ag dealer or product supplier. 8.0 Disposal Ensure that any persons handling the machine are aware that the machine may have been used to apply equipment should be worn.
  • Page 12: General Maintenance

    2. Disconnect the power supply. 3. Replace the PVC waterproof cover (if applicable). 4. Store in dry conditions to protect the machine and control system from moisture. WARNING! DO NOT JET WASH THIS MACHINE. Micro Meter Operating Manual & Parts List P12...
  • Page 13: Machine Mounting

    It is not practical to supply tailored mounting brackets for every implement on the market, and so the final attachment of the Micro Meter to the implement is the responsibility of the supplying dealer or end user. As Micro Meters are gravity fed machines hoses must be routed downhill with sufficient fall to allow the product to flow freely.
  • Page 14: Vari-Speed Controls

    (-) terminal. NOTE: Always replace any blown fuse with the same amp rated blade type fuse as the original one fitted. Control extension cables available. If required please contact your local Stocks Ag dealer. WARNING! Failure to connect to the vehicle battery may result in control function problems and possible damage to the vehicle battery and charging system must be in good condition to achieve the best results.
  • Page 15: Control Panel

    NOTE: Heavy Duty Cut Out Switch available: For more information please consult your local Stocks Ag dealer.
  • Page 16: Product Calibration

    1 minute catch test. NOTE: Feed shaft speeds are regulated by the Micro Meter, Vari-Speed or Micro Meter i-CON Drive Unit. It is the responsibility of the operator to ensure safe handling of the machine and the appropriate personal protection equipment is worn for the material being applied and to prevent contamination to the machine or the environment.
  • Page 17: I-Con Controls

    All cables and controls are fitted with matching plugs and sockets. Extension cables available. Any modification to the wiring, fuse holder or controls will invalidate any warranty claim and may affect the performance. Micro Meter Operating Manual & Parts List P17...
  • Page 18: I-Con Instrument Functions

    The instrument can be unlocked to activate the precision farming program as a cost option. This is something that can be requested when the machine is purchased or can be added at a later date. Please contact your local Stocks AG dealer for more details. Micro Meter Operating Manual & Parts List P18...
  • Page 19: I-Con Calibration

    NOTE: Recommended min speed 0.8kph - 1.2kph (if not see feed roller configuration). 17. Touch to save the new factor, it is advised to repeat the cali- bration two more times to ensure accuracy. Micro Meter Operating Manual & Parts List P19...
  • Page 20: Manual Calibration

    If the indicated speed range does not work for your operation, you must change the feed roll configuration or the type of feed roll to apply more or less seed, per revolution of the feed mechanism, as required. Once completed, recalibrate and note the new speed range. Micro Meter Operating Manual & Parts List P20...
  • Page 21: Feed Shaft Speed

    13.0 Feed Shaft Speed Feed shaft speed is controlled by the Micro Meter, Vari-Speed or Micro Meter i-CON Drive Unit Alternatively, if the units are being fitted with a mechanical drive system of some kind the shaft speed will be determined by the design of the system If changing feed rollers from Standard to Deep Groove, please contact your local dealer for more information.
  • Page 22: Product Calibration

    1 minute catch test. NOTE: Feed shaft speeds are regulated by the Micro Meter, Vari-Speed or Micro Meter i-CON Drive Unit. It is the responsibility of the operator to ensure safe handling of the machine and the appropriate personal protection equipment is worn for the material being applied and to prevent contamination to the machine or the environment.
  • Page 23: Micro Meter Add-On Parts Drawing

    15.0 Micro Meter Parts Drawing Micro Meter Operating Manual & Parts List P23...
  • Page 24: Micro Meter Add-On Parts List

    M5 x 25 Slot Head CSK Screw M5-014 M5 Flat Washer M5-017 M5 Nyloc Nut M6-004 M6x16 Hex Head Setscrew M6-006 M6x20 Button Head Setscrew M6-015 M6 Flat Washer M6-016 M6 Flat Washer Micro Meter Operating Manual & Parts List P24...
  • Page 25: Micro Meter Add-On Parts List Cont

    Decal “Serial No. / CE UKCA Mark” (not shown) MD002 Decal “Stocks AG” (not shown) MD020 Decal “Stocks MICRO-METER” (not shown) MD052 Warning Decal Kit (not shown) MD024 Decal “Made in Britain” (not shown) MD022 Decali-CON (not shown) Micro Meter Operating Manual & Parts List P25...
  • Page 26: Micro Meter Combi Parts Drawing

    16.0 Micro Meter Combi Parts Drawing Micro Meter Operating Manual & Parts List P26...
  • Page 27: Micro Meter Combi Parts List

    Reference only MM300B Combi Chassis M10-004 M10 x 25 Bolt M10-024 M10 Nyloc Nut M10-016 M10 Flat Washer M10-009A M10 x 45 Bolt For more information please contact your local Stocks AG dealer Micro Meter Operating Manual & Parts List P27...
  • Page 28 Notes Micro Meter Operating Manual & Parts List P28...