Dell PowerEdge 2970 Hardware Owner's Manual page 31

Dell poweredge 2970 servers: owners manual
Hide thumbs Also See for PowerEdge 2970:
Table of Contents

Advertisement

Table 1-7. System Messages (continued)
Message
Manufacturing mode
detected
Memory address line
failure at address , read
value expecting value
Memory double word logic
failure at address , read
value expecting value
Memory odd/even logic
failure at address, read
value expecting value
Memory write/read failure
at address , read value
expecting value
Memory tests terminated by
keystroke.
No boot device available
No boot sector on hard
drive
No timer tick interrupt
Not a boot diskette
PCI BIOS failed to install PCIe device BIOS (Option ROM)
Causes
System is in manufacturing mode.
Faulty or improperly installed memory
modules.
POST memory test terminated by
pressing the spacebar.
Faulty or missing optical/diskette
drive subsystem, hard drive, or hard-
drive subsystem, or no boot disk in
drive A.
Incorrect configuration settings in
System Setup program, or no
operating system on hard drive.
Faulty system board.
No operating system on diskette.
checksum failure detected during
shadowing.
Cables to expansion card(s) loose;
faulty or improperly installed
expansion card(s).
Corrective Actions
Reboot to take the system out of
manufacturing mode.
See "Troubleshooting System Memory"
on page 124.
Information only.
Use a bootable diskette, CD, or hard
drive. If the problem persists, see
"Troubleshooting a Diskette Drive" on
page 126, "Troubleshooting an Optical
Drive" on page 127, and
"Troubleshooting a Hard Drive" on
page 129. See "Using the System Setup
Program" on page 37 for information on
setting the order of boot devices.
Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
on page 37. If necessary, install the
operating system on your hard drive. See
your operating system documentation.
See ""Getting Help" on page 147."
Use a bootable diskette.
Reseat the expansion card(s). Ensure
that all appropriate cables are securely
connected to the expansion card(s). If
the problem persists, see
"Troubleshooting Expansion Cards" on
page 132.
About Your System
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents