Table 1-7. System Messages (continued)
Message
Diskette subsystem reset
failed
Drive not ready
Error: Incorrect memory
configuration
CPU n
!!*** Error: Remote Access
Controller initialization
failure *** RAC virtual
USB devices may not be
available...
Gate A20 failure
General failure
HyperTransport error
caused a system reset!
Please check the system
event log for details!
Invalid NVRAM
configuration, Resource
Re-allocated
Invalid PCIe card found in
the Internal_Storage slot!
Keyboard Controller
failure
30
About Your System
Causes
Faulty or improperly installed diskette
drive.
Diskette missing from or improperly
inserted in diskette drive.
The DIMM group for CPU n is
incorrectly configured and caused the
system to halt.
Remote Access Controller
initialization failure
Faulty keyboard controller; faulty
system board.
The operating system is unable to
carry out the command.
A fatal system error occurred and
caused the system to reboot.
System detected and corrected a
resource conflict.
The system halted because an invalid
PCIe expansion card is installed in the
dedicated storage controller slot.
Faulty keyboard controller; faulty
system board
Corrective Actions
Reseat diskette drive interface cable, or
power cable. If the problem persists, see
"Troubleshooting a Diskette Drive" on
page 126.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 126.
See "General Memory Module
Installation Guidelines" on page 91 for
memory configuration information. If
the problem persists, see
"Troubleshooting System Memory" on
page 124.
Ensure that the Remote Access
Controller is properly installed. See
"Installing a RAC Card" on page 81.
See "Getting Help" on page 147.
This message is usually followed by
specific information. Note the
information, and take the appropriate
action to resolve the problem.
Check the SEL for information that was
logged during the error. See the
applicable troubleshooting section in
"Troubleshooting Your System" on
page 115 for any faulty components
specified in the SEL.
No action is required.
Remove the PCIe expansion card and
install either the SAS or optional SAS
RAID controller in the dedicated slot.
See "Getting Help" on page 147.