Table 1-6. LCD Status Messages (continued)
Code
Text
E1421
CPU Init
E1422
CPU Machine Chk
E1610
PS # Missing
E1614
PS # Status
E1618
PS # Predictive
E161C
PS # Input Lost
PS # Input Range Power source for specified power
E1620
E1624
PS Redundancy
E1625
PS AC Current
E1710
I/O Channel Chk
Causes
The system BIOS has reported a
processor initialization error.
The system BIOS has reported a
machine check error.
No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
Power source for specified power
supply is unavailable, or out of
acceptable range.
supply is unavailable, or out of
acceptable range.
The power supply subsystem is no
longer redundant. If the last
supply fails, the system will go
down.
Power source is out of acceptable
range.
The system BIOS has reported an
I/O channel check.
Corrective Actions
See "Getting Help" on page 147.
See "Getting Help" on page 147.
See "Troubleshooting Power
Supplies" on page 122.
See "Troubleshooting Power
Supplies" on page 122.
See "Troubleshooting Power
Supplies" on page 122.
Check the AC power source for
the specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 122.
Check the AC power source for
the specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 122.
See "Troubleshooting Power
Supplies" on page 122.
Check the AC power source.
See "Getting Help" on page 147.
About Your System
23

Hide quick links:

Advertisement

Table of Contents
loading