Table 1-2. System-Board Jumper Descriptions - Dell OptiPlex GXi Service Manual

Dell optiplex gxi: service manual
Table of Contents

Advertisement

Dell OptiPlex GXi Systems Service Manual
1-22

Table 1-2. System-Board Jumper Descriptions

Jumper
Description
100
Reserved
*
133
Microprocessor
speed
166
Microprocessor
speed
200
Microprocessor
speed
233
Microprocessor
speed
PSWD
Password
enable or
disable
BIOS
Reserved
NICRST
NIC enable or
disable
* Not on all systems
Settings
Do not install jumper.
Install jumper if the microprocessor's
internal speed is 133 MHz; otherwise the
jumper should not be installed.
Install jumper if the microprocessor's
internal speed is 166 MHz; otherwise the
jumper should not be installed.
Install jumper if the microprocessor's
internal speed is 200 MHz; otherwise the
jumper should not be installed.
Install jumper if the microprocessor's
internal speed is 233 MHz; otherwise the
jumper should not be installed.
Install to enable the password feature.
Do not install jumper.
Service procedure only — Install jumper,
then boot the computer to clear the NIC set-
tings and reset the base address to 200h;
then remove the jumper to allow configura-
tion changes.