Datamax Mark II M-4206 Operator's Manual page 85

Label printer
Hide thumbs Also See for Mark II M-4206:
Table of Contents

Advertisement

Advanced Entry Calibration (continued)
Step
Operator Action
12
From the data collected in
Steps 10 and 11, where both
the sensor readings are above
20, subtract each Label Value
from the corresponding TOF
Value. These are the
Difference Values.
From the resulting list, find the
largest Difference Value (see
example below). Its associated
Gain Number will provide the
best algorithm for your media.
M-Class
Displayed Message
!
HBJO!USBO!!!!!!=zzz?+1
1!!!!!!!!!)1!.!42*!
!
Or, for reflective media:
HBJO!SFGM!!!!!!=zzz?+1
1!!!!!!!!!)1!.!42*!
For example, if your
Number
compiled data had the
values shown in this
table, Gain Number 8
would be chosen
because it has the
highest Difference
Value (146) where
both the Label Value
and the TOF Value
are above 20.
Both sensor readings must be above 20.
Gain
Label
TOF
Value
Value
00
255
254
01
251
240
02
241
213
03
231
182
04
219
150
05
212
119
06
200
88
07
189
58
08
178
32
09
167
19
10
156
17
11
146
16
12
136
15
...
...
...
31
116
14
32
112
14
Comment
Difference
Value
1
11
28
49
69
93
112
131
146
N/A
N/A
N/A
N/A
...
N/A
N/A
75