Calibration Mode - Button Functions - Datamax Mark II M-4206 Operator's Manual

Label printer
Hide thumbs Also See for Mark II M-4206:
Table of Contents

Advertisement

4.7 Calibration Mode – Button Functions
In 'Calibration' mode, the buttons allow the printer to adjust to the media being used. Calibration can be performed either
automatically or manually, as detailed below.
Notes: Before calibrating, ensure that the Printhead Carrier Assembly is latched down, that the cover is closed, and that the media
sensor has been set for the appropriate media type, see Section 4.5.2.
Printer and cutter faults are disabled during
printing "test" labels.
If at any time you wish to discard your changes and revert back to the previous calibration simply turn off power to the
printer. Also, Factory Defaults can be restored, see Section 6.7
To perform Calibration:
32
(Press and hold during power-up until the
CANCEL
Calibration Mode
PAUSE
Auto Media Calibration (See section 4.7.1)
(
Press and
FEED
Release
(
Press and
FEED
Hold
Prints the 'Test Label' for "test"
CANCEL
PAUSE
Saves the current values
+
and resumes
CANCEL
Media Sensor Calibration
PAUSE
Analyze for 'Paper'
FEED
Analyze for 'Backing or 'Mark'
CANCEL
Analyze 'Out of Media' condition
PAUSE
Accepts the current
+
values for "test"
CANCEL
and
STOP
)
Feeds one label for "test"
)
(Until Paused light turns off)
Normal Mode
(See section 4.7.2)
, but can still occur while
light turns off)
DONE
M-Class