Quick Links

Installation Manual
MULTI FUNCTION DISPLAY
TZT19F
Model
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATION ........................................................................................... ii
EQUIPMENT LISTS........................................................................................................ iv
1. MOUNTING.............................................................................................................1-1
1.1 Installation of Multi Function Display..................................................................................1-1
1.2 Installation of Transducers.................................................................................................1-4
2. WIRING....................................................................................................................2-1
2.1 Interface Connections (Rear of Unit) .................................................................................2-1
2.2 Composite Connector ........................................................................................................2-2
2.3 How to Secure and Waterproof Connections.....................................................................2-3
2.4 Power Cable ......................................................................................................................2-3
2.5 MULTI Cable......................................................................................................................2-4
2.6 DRS Radar Sensor Connections .......................................................................................2-5
2.7 Network Connection with Other TZT Series Units .............................................................2-5
2.8 NMEA 2000 Connector ......................................................................................................2-5
2.9 Transducer (Option).........................................................................................................2-10
2.10 Example TZT19F System Configurations ........................................................................2-11
3. HOW TO SET UP THE EQUIPMENT......................................................................3-1
3.1 How to Set Time Zone, Time Format and Language.........................................................3-3
3.2 How to Set Units of Measurement .....................................................................................3-4
3.3 Initial Setup ........................................................................................................................3-5
3.4 How to Set Up the Radar .................................................................................................3-11
3.5 How to Set Up the Fish Finder.........................................................................................3-14
3.6 Wireless LAN Setting .......................................................................................................3-19
3.7 Ferry Mode.......................................................................................................................3-21
3.8 How to Manage Your Charts............................................................................................3-21
3.9 IP Camera Setup .............................................................................................................3-24
APPX. 1 TRANSDUCER LIST .................................................................................AP-1
PACKING LIST(S) ....................................................................................................... A-1
OUTLINE DRAWING(S) .............................................................................................. D-1
INTERCONNECTION DIAGRAM(S) ........................................................................... S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TZT19F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Furuno TZT19F

  • Page 1: Table Of Contents

    2.7 Network Connection with Other TZT Series Units .............2-5 2.8 NMEA 2000 Connector ......................2-5 2.9 Transducer (Option)......................2-10 2.10 Example TZT19F System Configurations ................2-11 3. HOW TO SET UP THE EQUIPMENT..............3-1 3.1 How to Set Time Zone, Time Format and Language............3-3 3.2 How to Set Units of Measurement ..................3-4...
  • Page 2 ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN A : JAN 2020 Printed in Japan All rights reserved. F : JUN . 04, 2024 Pub. No. IME-45120-F (TEHI ) TZT19F 0 0 0 1 9 7 1 0 8 1 5...
  • Page 3: Safety Instructions

    Steering Standard the equipment. Model compass compass If your vessel is configured with TZT19F 0.65 m 0.40 m an autopilot system, install an autopilot control unit (or emer- gency autopilot stop button) at each helm station, to allow you to disable the autopilot in an emergency.
  • Page 4: System Configuration

    : Use an after-market PoE hub. The NETGEAR GS108PE is confirmed as compatible. Compatibility tests are limited to general use as part of this configuration and in no way indicates overall capability. Further, FURUNO cannot guarantee the functionality of any after-market hub.
  • Page 5 SYSTEM CONFIGURATION TZT series network connection The TZT series can be connected on the same network with the following combinations. TZtouch: TZtouch2: TZtouchXL: TZT9/14/BB TZTL12F/15F/TZT2BB TZT10X/13X/16X/22X/24X TZtouch3:TZT9F/12F/ 16F/19F...
  • Page 6: Equipment Lists

    EQUIPMENT LISTS Standard supply Name Type Code No. Remarks Multi Function Display TZT19F Installation Materials CP19-02600 000-037-169 Accessories FP26-00401 001-175-940 Optional supply Name Type Code No. Remarks Operator’s Manual OME-45120-* 001-635-380 Network HUB HUB-101 000-011-762 NMEA Data Con- IF-NMEA2K2 000-037-670...
  • Page 7 EQUIPMENT LISTS Name Type Code No. Remarks Cable Assy. FRU-F12F12-100C 001-560-390 FRU-F12F12-200C 001-560-400 FRU-F7F7-100C 001-560-420 FRU-F7F7-200C 001-560-430 FRU-CCB12-DA-10M*3 001-608-450 For transducer extension Fish Finder Power DI-FFAMP 000-037-174 For 2 to 3 kW Dual-frequen- Amplifier cy CHIRP transducers Transducer (for in- 000-015-204 600 W 520-5PSD...
  • Page 8 EQUIPMENT LISTS Name Type Code No. Remarks CHIRP Transducer 000-037-609 1 kW B265LH-FJ12 (for internal fish find- 000-037-610 CM265LH-FJ12 000-037-611 TM265LH-FJ12 CHIRP Transducer PM111LHG 000-027-404 2 kW (Requires DI- CM599LHG 000-027-406 2 to 3 kW FFAMP/DFF3-UHD) CM599LM 000-027-407 Thru-Hull Pipe TRB-1100(1) 000-027-409 TRB-1000(1)
  • Page 9: Mounting

    Wrong installation or maintenance can void the warranty. Mounting considerations When selecting a mounting location for your TZT19F, keep the following in mind: • The temperature at the mounting location shall be between -15°C and +55°C. • The humidity at the mounting location shall be 93% or less at 40°C.
  • Page 10 A tool can be used to fasten the wing nuts; use caution so as not to damage the wings or thread. 3. Connect all cables at the back of the TZT19F. (See chapter 2.) 4. Attach flush mount sponges to the bezel of TZT19F.
  • Page 11 1. MOUNTING 6. Attach the flush mount fixture to the TZT19F with hex bolts. ② ② Set the TZT19F to the cutout. ① ① Attach the flush mounting Attach the flush mounting plate to the TZT19F. plate to the TZT19F.
  • Page 12: Installation Of Transducers

    1. MOUNTING Installation of Transducers CAUTION Do not cover the transducer with FRP resin. The heat generated when the resin hardens may damage the transducer. CHIRP transduc- ers are especially vulnerable to heat. Note: For instructions regarding installation ø22 ø24 of network fish finder transducers, see the re- spective manual.
  • Page 13 1. MOUNTING • The transducer must always remain submerged, even when the boat is rolling, pitching or up on a plane at high speed. • A practical choice would be somewhere between 1/3 and 1/2 of your boat's length from the stern. For planing hulls, a practical location is generally rather far astern, so that the transducer is always in water regardless of the planing attitude.
  • Page 14 1. MOUNTING 1.2.2 How to mount a transducer inside the hull NOTICE This installation method affects the ability to detect the bottom, fish and other objects because the ultrasound pulse is weakened when it passes through the hull. Therefore, refrain from this mounting method for a transducer that supports the RezBoost™...
  • Page 15 7. Confirm the available fish finder from the list of available sounders, then tap the appropriate fish finder. For the purpose of this example, the default setting [TZT19F] (internal sounder) is selected as the source. 8. Tap the [<] icon to return to the [Fish Finder] menu.
  • Page 16 It takes 24 to 72 hours to harden completely. 5. Turn the power on and change the menu setting as shown below. See section 3.3 for how to use the menu. 1) Tap the [FURUNO] icon ( ) to show the home screen and dis- play mode settings.
  • Page 17 1. MOUNTING 1.2.3 How to install the transom mount transducer The optional transom mount transducer is very commonly employed, usually on relatively small I/O or outboard boats. Do not use this method on an inboard motor boat because turbulence is created by the propeller ahead of the transducer. DO NOT over-tighten screws, to prevent damage to the transducer.
  • Page 18 1. MOUNTING Transducer preparation Before putting your boat in water, wipe the face of the transducer thoroughly with a liquid detergent. This will lessen the time necessary for the transducer to have good contact with the water. Otherwise the time required for complete "saturation" will be lengthened and performance will be reduced.
  • Page 19 1. MOUNTING 525STID-PWD The optional triducer 525STID-PWD is designed for transom mounting. Select the location where influences from Height without bubbles and turbulences to ensure the speed sensor 191 mm (7-1/2") best performance. Allow adequate space above the bracket for it to release and ro- Height with Height Height...
  • Page 20 1. MOUNTING If you do not know the transom angle, temporarily attach the bracket and sensor to the transom to determine if the plastic shim is needed. 11º transom angle 2º-10º 19º-22º NO SHIM transom transom angle angle shim with shim with taper down taper up...
  • Page 21 1. MOUNTING 5. Using the vertical adjustment space on the bracket slots, slide the sensor up or down to provide a projection of 3 mm Cable cover (1/8”). Tighten the screws. Cable clamp 50 mm (2") Hull projection 3 mm (1/8") How to attach the sensor to the bracket 1.
  • Page 22 1. MOUNTING 4. At each of the marked locations, use a 3 mm or 1/8” bit to drill a hole 10 mm (3/8”) deep. The prevent drilling too deeply, wrap masking tape around the bit 10 mm (3/8”) from the point. 5.
  • Page 23: Wiring

    WIRING Interface Connections (Rear of Unit) Rear of TZT19F Rear of TZT19F 12-10P Ground wire Conversion Cable (Local supply, FRU-CCB12-MJ-01 IV-8sq.)* (0.4m, supplied) Core Power Cable TO: Ship’s ground FRU-3P-FF-A002M- 001 2 m, supplied) TO: 12 to 24 VDC Transducer Cable...
  • Page 24: Composite Connector

    You can connect to external devices such as buzzers and event switches. See section 2.5 for details. USB port The TZT19F has two USB Ver. 2.0 ports which can be used to connect an optional SD card unit or remote control unit, and to be operated from touch device or PC mouse.
  • Page 25: How To Secure And Waterproof Connections

    How to Secure and Waterproof Connections Where the unit is exposed to water spray or moisture, all the connectors and MULTI cable connections to the TZT19F must have at least IPx6 waterproof rating. All unused cable ends should be covered for protection.
  • Page 26: Multi Cable

    How to set up NMEA 0183 data output Note: To set up data input from NMEA 0183 equipment, see "NMEA 0183 data input via IF-NMEA2K2" on page 2-7. 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings.
  • Page 27: Drs Radar Sensor Connections

    (see page iii for the details). However, for configurations with one or more TZT2BB included, the maximum number of networked NavNet TZ- touch units is four. For example, a configuration with one TZT19F and one TZT12F can have two TZT2BB units connected.
  • Page 28 , the TZT19F can display engine information on a dedicated Yamaha engine status display. How to connect the engine The TZT19F connects to the Yamaha engine network via the Yamaha Interface Unit. Arrange the Yamaha Interface Unit through a local Yamaha representative. Yamaha Interface Unit...
  • Page 29 /Command Link Plus /Helm Master How to set up the engine display Once the TZT19F detects the Yamaha engine network, the engine can be set up on [Settings][Initial Setup][YAMAHA ENGINE SETUP]. See section 3.3 for details. 2.8.3 NMEA 0183 data input via IF-NMEA2K2 Note: To output NMEA 0183 data, see paragraph 2.5.1.
  • Page 30 2. WIRING 2.8.4 NMEA 2000 input/output Input PGN Description 059392 ISO Acknowledgment 059904 ISO Request 060160 ISO Transport Protocol, Data Transfer 060416 ISO Transport Protocol, Connection Management - BAM group function 060928 ISO Address Claim Self Test Group Function 061184 HID Keyboard/Keypad Usage HID Mouse Report Descriptor (Proprietary PGN) 065240...
  • Page 31 Note that only one TZT19F will output NMEA 2000 data on the network at a time: the TZT19F which is powered ON first. If that display is turned OFF, another will take its place to output the data.
  • Page 32: Transducer (Option)

    The 12-10P conversion cable (FRU-CCB12-MJ-01, 0.4m, supplied) is required when connecting a transducer that has a 10-pin connector to TZT19F. Matching Box MB- 1100 is also required when connecting a 1kW transducer to TZT19F. See the inter- connection diagram for transducer connection. The transducer that has a 12-pin con- nector does not require the 12-10P conversion cable.
  • Page 33: Example Tzt19F System Configurations

    2. WIRING 2.10 Example TZT19F System Configurations Mid/Large-size vessels (external GPS, fish finder, radar) This is a sample of the chart plotter/radar/fish finder installation. Refer to "SYSTEM CONFIGURATION" on page ii for more details. Radar Sensor DRS6A X-Class/DRS12A X-Class/ DRS25A...
  • Page 34 2. WIRING This page is intentionally left blank. 2-12...
  • Page 35: How To Set Up The Equipment

    (power switch) to turn the power on. 2. After the startup process completes, the last used display appears and a warning message is displayed. After reading the message, tap [OK]. 3. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings.
  • Page 36 3. HOW TO SET UP THE EQUIPMENT 4. Tap [Settings] to open the [Settings] menu. 5. Scroll the menu to show [Initial Setup], then tap [Initial Setup]. Back icon Menu title Close icon Preview screen Preview screen Changes made in the Changes made in the Menu Menu...
  • Page 37: How To Set Time Zone, Time Format And Language

    Before setting up your equipment, select the time zone, language and units to use on your equipment as shown below. 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings. 2. Tap [Settings] to show the [Settings] menu.
  • Page 38: How To Set Units Of Measurement

    3. HOW TO SET UP THE EQUIPMENT How to Set Units of Measurement 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings. 2. Tap [Settings] to show the [Settings] menu. 3. Scroll the main menu to display [Units], then tap [Units].
  • Page 39: Initial Setup

    Note: Some units are set to metric in this section, actual setting ranges vary depending on the unit of measurement set in the [Units] menu. 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings.
  • Page 40 3. HOW TO SET UP THE EQUIPMENT Menu item Description Options (setting range) [Graphic Instruments See "[Initial Setup] menu - [GRAPHIC INSTRUMENTS Setup] SETUP]" on page 3-9. [HOME] Screen Setup Menu item Description Options (setting range) [Factory Reset] Click [OK] to restore the [HOME] screen’s default settings. Manual Fuel Management Setup Menu item Description...
  • Page 41 Select the source for each data to input to the system. If two or more sources are connected for a data, select one using the pull-down dialog box. The FURUNO products are shown at the upper part of the list. [Sensor List] Show the information for sensors connected to your equipment.
  • Page 42 3. HOW TO SET UP THE EQUIPMENT [Initial Setup] menu - [NETWORK SENSOR SETUP] The [NETWORK SENSOR SETUP] section allows you to set up compatible FURUNO NMEA 2000 sensors. Calibrations and offsets applied in this menu are also applied to the sensor itself.
  • Page 43 3. HOW TO SET UP THE EQUIPMENT Menu item Description Option (setting range) [Quick Self Test] Displays various details regarding the TZT19F, radar and fish finder. [Certification Mark] Displays relevant certification for this equipment. [Service] For the service technician. [Event Input Configu- Set the function for the event switch.
  • Page 44 [Initial Setup] menu - [Engine & Tank Automatic Setup] The TZT19F will automatically detect engines and tanks connected to the same net- work. This is the recommended method for setting up engines and tanks. [Initial Setup] menu - [Engine & Tank Manual Setup] The manual set up method should only be used if the automatic setup did not correctly detect your engines or tanks.
  • Page 45: How To Set Up The Radar

    3. HOW TO SET UP THE EQUIPMENT How to Set Up the Radar 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings. 2. Tap [Radar] from the [Settings] menu. 3. Tap [Radar Source], then select the appropriate radar sensor.
  • Page 46 3. HOW TO SET UP THE EQUIPMENT Menu item Description Options (setting range) [Tuning Source] Select a display in the dual range display to [Range1], [Range2] manually tune. Not available (grayed out) with DRS4DL+/ DRS2D-NXT/DRS4D-NXT/DRS6A-NXT/ DRS12A-NXT/DRS25A-NXT. [Manual Tuning] Manually tune the radar. [-50] to [50] Not available (grayed out) with DRS2D- NXT/DRS4D-NXT/DRS6A-NXT/DRS12A-...
  • Page 47 Zoom out Zoom out Radar indications 2. Turn the vessel’s bow toward a target. 3. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings. 4. Tap [Radar] to show the [Radar] menu. 5. Tap [Antenna Heading Align].
  • Page 48: How To Set Up The Fish Finder

    Note 2: For DFF-3D setup instructions, see the DFF-3D operator’s manual. 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings.
  • Page 49 3. HOW TO SET UP THE EQUIPMENT Options Menu item Description (setting range) [Transmission For- Select whether to transmit high and low frequencies simul- [Parallel], [Se- mat] taneously or with a time delay. Normally, use [Parallel], quentialA], [Se- which transmits the frequencies simultaneously. If you en- quentialB]* counter interference near the bottom, select [SequentialA], [SequentialB] in order to suppress the interference.
  • Page 50 • [Manual]: Manually set up the transducer. • [Model]: Select the appropriate transducer model (for FURUNO or AIRMAR transducers). [Model Number] Select the appropriate model number from the list. Note: Only available when [Transducer Setup Type] is set to [Model].
  • Page 51 3. HOW TO SET UP THE EQUIPMENT Options Menu item Description (setting range) [Reset Default Set- Reset the Transducer Setup menu settings to default. [OK], [Cancel] tings] *: Shown with connection of DFF3. When [Transducer Setup Type] is set to [Model] and connected to DFF3 Menu item Description [High Frequency]...
  • Page 52 Set the power of the transducer connected to the low frequency side. ?Power LF] Motion sensor menu Note 1: For connection of NMEA0183 equipment to the TZT19F, ask your FURUNO dealer to set up the equipment. Note 2: To use the heaving function, the following settings are required at the satellite compass.
  • Page 53: Wireless Lan Setting

    Bow/Stern for LF Options Menu item Description (setting range) [Motion Sensor Select the sensor connected to your TZT19F unit. For all [NMEA2000], Type] sensors other than SC-50 and SC-110, select [NMEA0183] [NMEA2000]. Note: This menu item is not available when [Fish Finder Source] is set to [TZT19F].
  • Page 54 How to create a wireless LAN network Smart devices connected to this wireless network may also connect directly to the unit, allowing use of the TZT19F applications. 1. Tap the [FURUNO] icon ( ) to show the home screen and display mode settings.
  • Page 55: Ferry Mode

    Note 2: When two or more units share an unlock code, you need to get an unlock code again if you change the [Chart Master Device]. For example, if the TZT19F that was used as the “primary” ([Chart Master Device] setting: [ON]) is used as the “secondary”...
  • Page 56 3.8.2 How to update or add charts Free (USA and NOAA) and for-fee compatible charts are provided by FURUNO and Mapmedia. Go to the URL shown below to download Mapmedia charts. For FURUNO- supplied charts, contact your local FURUNO dealer.
  • Page 57 3. HOW TO SET UP THE EQUIPMENT 3.8.3 How to view your charts Tap the [FURUNO] icon ( ) to show the home screen, then tap [Charts] to display your charts catalog. Tap to show [FIlter charts] pop-up menu. Tap to dowload chart unlock codes.
  • Page 58: Ip Camera Setup

    3. HOW TO SET UP THE EQUIPMENT How to hide unnecessary charts on the chart catalog list 1. Tap [Filter] on the chart catalog list title bar to show the [Filter charts] window. 2. Select [OFF] for the items that you want to hide.
  • Page 59: Appx. 1 Transducer List

    APPX. 1 TRANSDUCER LIST The table below available transducers and whether they are compatible with the functions listed. Optional transducers Standard transducers (CW narrow band) Model ACCU-FISH Bottom Disc. RezBoost Remarks 520-5PSD 600 W 520-5MSD 525-5PWD 525STID-MSD 525STID-PWD 520-PLD 525T-BSD 525T-PWD 525T-LTD/12 525T-LTD/20...
  • Page 60 APPX. 1 TRANSDUCER LIST CHIRP transducers Model ACCU-FISH Bottom Disc. RezBoost Remarks TM150M 300W B-75L B-75H 600W B-175H B-175L B265LH-FJ12 CM265LH-FJ12 TM265LH-FJ12 PM111LHG 2 kW (Requires DFF3- UHD/DI-FFAMP) CM599LHG 2 to 3 kW (Requires DFF3-UHD/DI-FFAMP) CM599LM Other compatible transducers Standard transducers (CW narrow band) Model ACCU-FISH Bottom Disc.
  • Page 61 APPX. 1 TRANSDUCER LIST CHIRP transducers (dual frequency) Model ACCU-FISH Bottom Disc. RezBoost Remarks B275LHW-FJ12 1 kW B265LM-FJ12 CM265LM-FJ12 CM275LHW-FJ12 TM265LM-FJ12 TM275LHW-FJ12 CHIRP Side Scan transducers Model ACCU-FISH Bottom Disc. RezBoost Remarks 225T-TM904 150 W 225T-SS904 225T-PR904 CHIRP transducers (dual frequency, requires the DFF3-UHD/DI-FFAMP) Model ACCU-FISH Bottom Disc.
  • Page 63 C C ODE NO. 001‑175‑940‑00 26AD‑X‑9501 ‑9 TYPE FP26‑00401 付属品表 ACCESSORIES 番 号 名  称  型名/規格 数量 略  図 用途/備考 Q'TY  NO.  NAME OUTLINE DESCRIPTIONS REMARKS フィルタークリーナー 19‑028‑3125‑7 LCD CLEANING CLOTH CODE  100‑360‑677‑10 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) FURUNO ELECTRIC CO .,LTD.
  • Page 65 11/Nov/2019 H.MAKI...
  • Page 66 デジタル署名者 : 牧 宏昌 牧 宏昌 '付 : 2023.12.20 17:36:06 +09'00'...