1. The 1000 Series HT high temperature dishwasher sanitizes with 180-195° F/82-91° C
hot final rinse water.
2. Do not connect a sanitizer chemical dispenser to the 1000 Series HT.
3. You may wish to contact a chemical supplier to supply the chemical dispensers
and chemicals for liquid detergent and liquid rinse-aid. (Consult your local listings).
4. The chemical supplier must adjust their dispensers to provide the proper dosages
for the installed dispensing system.
5. The factory may have supplied the chemical dispensing system as an option. Your
chemical supplier must adjust factory dispensers for the chemicals supplied also.
Manual dosing of detergent or rinse-aid is NOT RECOMMENDED for the 1000 Series HT
dishwasher. Poor washing results may result if manual dosing is employed.
Cartridge detergent systems are NOT RECOMMENDED for the 1000 Series HT
dishwasher. Poor washing results may result if installed on this model.
6. The factory recommends that the chemical injectors be installed in the right
back corner of the hood as shown below.
Factory installed injection points
Chemical Dispensers (1000 Series HT)
Note:
Note:
1000 Series HT - Installation Guide
Installation Guide
Recommended
locations
for chemical injectors
for dispensing
systems
supplied by others.
Continued on page 10