Explication of warning symbols ��������������������������������������������������������������������7 EN ISO 12100 and DIN 12880� A copy of the complete declaration of conformity or further declarations of conformity can be Safety instructions ����������������������������������������������������������������������������������������8 requested at sales@ika�com� Intended use ����������������������������������������������������������������������������������������������12 Explication of warning symbols Useful information ������������������������������������������������������������������������������������ 13...
› The feet of the device must be clean and undamaged� Correct / Result! › Please note that the INC 125 FC digital can only be stacked in the lower position� The Shows the correct execution or the result of an action step�...
› Check the device and accessories beforehand for damage each time when you use them� Do not use damaged components� › Safe operation is only guaranteed with the accessories described in the ”Accessories” section� › Only use IKA approved accessories� › Use only original IKA spare parts�...
Intended use Useful information /// Use /// Material The device is suitable for tempering non-explosive, non-flammable or harmless substance and The inner chamber of the device is made of high quality stainless steel AISI 304� The inner door objects� It is also suitable for drying e�g� glassware or warm storing of liquids in container� is made of tempered glass�...
This menu shows how the values can be entered after the respective temperatures are approached and with an external measuring device cross-checked (calibrated)� 3-point calibration and offset [ºC] Point 3 INC 125 FC digital Hexagon socket offset screw key Point 2 USB cable Hose adapter...
Installation Notice! When lifting the device, do not use the door / door handle� This may damage the device� /// Transportation / setting down the device Warning! › Beware of the high dead weight of the device when transporting� › The device should only be transported by qualified persons with suitable handling equipment, such as a forklift and pallet truck! The device can be transported: - With a forklift truck...
Page 10
/// Placing the drain hose in laboratory drain › Detach the end of the hose from the holder › Extend the drain hose as required using the enclosed hose adapter min. 150 mm Water caused by condensation or defrosting is directed into the drain hose at the rear of the device�...
Page 11
/// Inserting the shelves › Insert the shelves › Open the door › Open the glass door /// Correctly loading...
/// Connecting to power Notice! The socket used must be earthed (fitted with earth contact)� Observe the ambient conditions (temperature, humidity etc�) listed under “Technical Data”� 220 - 240 V ~ 50/60 Hz 1200 W IP 20 Note: › Do not place the samples directly on the floor of the inner chamber of the device� Notice! ›...
Page 13
/// Other installation information › Attach both devices together (Stacking two devices) › Attach the lower device to the wall (see section "Setting up / Fixing the device to the wall")� › Place the second device, INC 125 F or FS digital, on top of the first� Max.
Page 14
› Attach the upper device to the wall › Placing the drain hoses in laboratory drain Detach the end of the hose from the holder Extend the drain hose as required using the enclosed hose adapter Note: › The screws used for fixing is selected according to the wall conditions and is not included� ›...
Operator panel and display /// Explanation of the control elements /// Explanation of symbols on the working screen 5 6 7 14 15 Item Designation Function Temperature value Display the settings and actual temperature value� "SET" symbol Indicate the set value is shown on the display� Fan status symbol Indicate the fan is activated / deactivated�...
Operation /// Setting the temperature Notice! Before commissioning, make sure that the device has not been moved in one hour� /// Switching on Min. Max.
/// Setting the fan speed › Set the fan speed › Activating the fan speed setting Note: Press the multifunction key (F) to activate the fan speed setting� The fan symbol blinks� Then, the fan speed value can be adjusted by rotating the control knob (H)� Min.
Page 18
/// Setting Counter (C) / Timer (T) or Timer Auto (Ts) › Confirm the setting of the fan speed value and start the fan › Switch between Counter (C) / Timer (T) / Timer Auto (Ts)
Page 19
/// Starting tempering function › Adjust and confirm the Timer (T) or Timer Auto (Ts) value Note: At set temperatures below the ambient temperature, the cooling unit switches on automatically� Please note that ice may form in the interior during cooling mode�...
Page 20
/// Locking / unlocking the settings Note: Counter (C): › If the "Counter (C)" function is activated, the counter automatically starts to run from 00:00:00 [h:min:sec] to the maximum value (99:23:59 [d:h:min]) when the tempering function is started� › If the device running time exceeds 24 hours, the time range switch from [h:min:sec] to [d:h:min] automatically�...
/// Stopping tempering function /// Activate standby status Note: When switching the device to standby status, if the device chamber temperature is higher than 50 °C, the actual temperature is displayed, e�g� 70 °C and "hot" symbol blinks� Menu navigation and structure /// Menu navigation ›...
/// Menu structure /// Menu details Default settings Operating mode: Operating mode Activated In this menu item you can choose between three different operating modes� Mode A: All settings will be stored if the device is switched off or disconnected from the power supply�...
Page 23
Alarm and key tone: Decontamination: In this menu option, you can select and activate alarm and key tone� In this menu option, you can perform decontamination to the chamber of the device� BEEP (on): Alarm and key tone is activated� Decontamination (off): Deactivate the decontamination function�...
Page 24
Press menu button to go back to the working screen� Calibration: The device is calibrated and adjusted in the factory� Note: The decontamination process can be stopped by pushing the control knob for 2 seconds� Individual sample loading and ambient condition might influence the temperature behaviour of The "dcon StoP?"...
First, download the latest driver for IKA devices with USB interface from: www.ika.com/ika/lws/download/usb-driver.zip. Install the driver by running the setup file� Connect the IKA device through the USB data cable to the PC� The data communication is via a virtual COM port�...
1�1)� The NAMUR commands and the additional specific IKA commands serve only as low level commands for communication between the device and the PC� With a suitable terminal or /// Connections between device and external devices: communications programme these commands can be transmitted directly to the device�...
For cleaning disconnect the mains plug! Solutions › Contact IKA service department� Use only cleaning agents which have been approved by IKA to clean the devices: These are: water (containing surfactant) and isopropyl alcohol� E 10322713/10332713 › Wear protective gloves during cleaning the devices�...
Page 28
Plastic parts: Do not clean the operating panel and other plastic parts of the chamber with abrasive or solvent-based cleaning agents� Glass surface: Clean the glass surface with commercial glass cleaning agent� Dust filter: To keep the full cooling performance, the dust filter of the device must be checked regularly and cleaned if necessary�...
› Device type� › Serial number, see type plate › Item and designation of the spare part, see: www.ika.com, spare parts diagram and spare parts list� › Software version (Briefly visible in the display when the device is switched on)�...
230 ± 10 % / 115 ± 10 % / 100 ± 10 % In accordance with IKA terms of sale and delivery, the warranty period is 24 months� For claims under the warranty please contact your local dealer� You may also send the machine...
Page 31
IKA Works Spain, S. L. Phone: +254 112 323 745 Phone: +254 112 323 745 Barcelona sales�kenya@ika�com sales�uganda@ika�com sales�spain@ika�com Discover and order the fascinating products of IKA online: www.ika.com IKAworldwide IKAworldwide /// #lookattheblue @IKAworldwide Technical specifications may be changed without prior notice�...
Need help?
Do you have a question about the INC 125 FC digital and is the answer not in the manual?
Questions and answers