WARNING:
Whenever wiring is to be done to the terminal strip of the
detector, make sure ALL sources of power have been disconnected. Terminals
3 through 9 may be powered from sources other than those supplying the
metal detector. Caution should be used when working on machinery as
components may stop and start automatically without warning.
TERMINAL
LI
L2
GND
Fl
3
4
F2
5
F2
6
7
8
9
A
B
C
D
TERMINAL CONNECTIONS
FUNCTION
POWER INPUT - Hot line
POWER INPUT - Neutral line
POWER INPUT - Ground line
HOT LINE Output - FUSED – Can be used as a
power source for unpowered contacts.
Output 1 - Isolated unpowered contacts. Keypad
selectable as normally open or normally closed.
NEUTRAL LINE Output – FUSED - Used as a return
line for reject devices, light, or alarms.
Output 2 - Internally supplied power Output to control
reject devices, lights, or alarms. Keypad selectable as
normally open or normally closed.
NEUTRAL LINE Output - FUSED - Spare.
Output 3 - Isolated unpowered contacts. Keypad
selectable as normally open or normally closed.
Output 4 - Isolated unpowered contacts. Always
configured as normally open. Delay and operate
times not adjustable.
+5V SUPPLY (.5A Max) – For use with external pulse
generating circuits.
PULSE COUNTER INPUT - Used by variable speed
conveyors to automatically correct the delay and
operate time to compensate for changes in belt speed.
MANUAL RESET INPUT - Input for normally open
external push-button used to manually reset metal
detector after a detection.
COMMON - Used as a common input for pulse
counter or manual reset controls.