BALANCE ADJUST
In order for the metal detector to operate at peak sensitivity the
receiver coils of the search head must be maintained at the correct
balance. The detector has automatic circuitry built in to maintain the
balance of the coils and this adjustment would not normally be required.
On occasion balance adjustment may be necessary due to extreme changes in
operating environment, physical changes, or aging of the metal detector
components. To adjust the balance use menus 55 & 56 and the balance access
hole on the front of the control panel. Rotate the balance adjust for the
minimum reading on the display.