INSTALLATION
MECHANICAL INSTALLATION
λ The detector must be bolted securely in position, but do not twist or
strain it in any way.
λ Nothing should rest on the search head or touch the sides of it.
λ All cover screws, bolts, etc., in the vicinity of the detector must be
tight for correct operation. Two pieces of metal making intermittent
contact may cause false triggers.
λ Do not modify the metal detector or its wiring in any way.
λ Do not attach rollers, guide plates, markers, or electronic sensing
devices to any part of the search head.
λ Product pipes with emulsions should pass through the center of the
detector opening, without touching the walls of the aperture.
( If a remote control cabinet is used, the connecting conduit must be
secured to prevent movement which could cause false triggers of the metal
detector. We recommend fastening the conduit securely every 12".
METAL-FREE AREA REQUIREMENTS
( The metal detector should be installed away from all pulleys and motors.
Keep all fixed and moving metal outside of the metal-free zone as
described in Fig. 1.
( There should be no metal pipes, conduit, supports, or guides near or
passing through the metal detector search aperture. Keep metal away!