Operation
c) The ECO mode is turned on when the Heating Air Speed button
(7)
is pressed
for the third time, and the ECO indicator light comes on. The operating rules of ECO
mode are as follows:
1) The default setting temperature is 25°C and 18°C. When the ambient temperature
is lower than 18°C, the heating wire runs at the high level. When the ambient
temperature is equal to or greater than 18°C and lower than 25°C, the heating wire
will run at the low level. When the ambient temperature is equal to or greater than
25°C, the heating wire turns off.
2) After the ECO mode is turned on, the heating wire turns off when the ambient
temperature rises to 25°C, the fan will turn off after a delay of 10 seconds, and
oscillation stops (if it has been turned on before). Others remain unchanged. When
the ambient temperature drops 2°C lower than the set temperature (i.e. 23°C), the
heating wire, fan and oscillation (if they have been turned on before) turn on again.
3) After the ECO mode is turned on, the heating wire turns to low level operation
when the ambient temperature rises to 18°C. When the ambient temperature
drops 2°C below the set temperature (i.e. 16°C), the heating wire turns to high level
operation. During ECO function operation, theh high and low heat settings, as well
as the cooling air function is not adjustable. All other functions are normal. The
working cycle of the button control is: low level heating air - high level heating air
- ECO mode - low level heating air...... Note: The high level and low level heating air
operate at level 2 cooling air in the heating state, and the cooling air speed is not
adjustable.
SCREEN OFF
In the power-on state, press the Screen Off button
(8)
to enter the screen off state.
The LED screen and indicator will turn off. You can press any button to restore the
last display state.
OTHER
a) Tilt protection function. If the machine tilts down, all functions are turned off and
the indicator lights all turn off. It enters the standby state after recovery.
b) Uninterruptible power memory function. If it is not the first time to turn on, press
the On/Standby button
(1)
in the standby state to turn on and keep the state before
shutting down, except for the timer function.
c) When in heating mode, after the unit has operated continuously for 24 hours
without any input, the unit will automatically enter the standby state.