Summary of Contents for AQUAPHOR APRO 100

  • Page 1 APRO 100 / APRO 100 PRO MANUAL...
  • Page 2: Table Of Contents

    Table of Contents System Overview........................... 5 1.1. Description ............................ 5 1.2. System Application........................5 1.3. System package list ........................6 1.4. Dimensions ............................ 6 1.5. System’s equipment list ........................ 6 1.6. System’s scheme ........................... 7 1.7. System’s operation description ....................8 Electric schemes ............................
  • Page 3: System Overview

    1.2. System Application APRO 100 system is installed in various facilities such as food establishments, cafes, and restaurants, where the electrical networks, water supply, and sanitation mains meet the requirements outlined in this manual.
  • Page 4: System Package List

    APRO 100 or APRO 100 PRO system 1 unit Gross prefilter (optional) 1 set  EFG 112/250-5 cartridge  Gross Housing  B510-12 (APRO 100 PRO) or B510-12H (APRO 100) cartridge Supply pipe 1 unit Concentrate drain clamp 1 unit Concentrate drainage pipe...
  • Page 5: System's Scheme

    1.6. System’s scheme TP-APRO-100-PRO-R01...
  • Page 6: System's Operation Description

    1.7. System’s operation description a. When power is supplied to the unit, the initial startup procedure begins. b. Pre-treated water is directed to the reverse osmosis unit. Attention: In case of replacing modules or sorbents in the pre-filtration unit, they must be rinsed and put into normal operation before supplying water to the reverse osmosis system.
  • Page 7: Electric Schemes

    2. Electric schemes TP-APRO-100-PRO-R01...
  • Page 8 TP-APRO-100-PRO-R01...
  • Page 9: Connections

    3. Connections TP-APRO-100-PRO-R01...
  • Page 10: Technical Requirements

    4. Technical requirements 4.1. Feed Water Requirements Designation Unit Value Water supply for the reverse osmosis system Temperature °C 5 - 30 Turbidity factor <1 Blocking factor (sludge / <3 index of sedimentation density) Flow pressure 2.5 - 6 Salinity <1500 Total hardness °dH...
  • Page 11: Reverse Osmosis Characteristics

    4.3. Reverse Osmosis characteristics Designation Unit Value Permeate Operating pressure max. Control With 20 °C With 10 °C Connections Raw water 3/8’’ Concentrate ¼ ’’ Permeate ¼ ’’ Pressure fluctuations max. ± 1 RO salt retention rate max. 90 - 95 Operating temperature °C 30 - 40...
  • Page 12: Optional Prefilter Data (Viking)

    4.4. Optional prefilter data (Viking) Application Drinking water purification Filtered contaminants Mechanical impurities, Mechanical impurities, >1 colloidal iron, residual µm active chlorine, organic Colloidal iron, % >80 substances (phenol, Residual active chlorine, >90 benzene), heavy metal ions (lead, cadmium) Organic substances >90 (phenol, benzene), % Heavy metal ions (lead,...
  • Page 13: Installation

    5. Installation 5.1. System’s installation The system should be stored in a dry place at a temperature between +5 °C and +40 °C. 1. Unpack the system and place it to the permanent place of work. 2. Prefiltration installation (optional): a.
  • Page 14: Viking Prefiltration Module Installation (Optional)

    5.2. Viking prefiltration module installation (OPTIONAL) The pre-filter needs no specific servicing during its service life, except the timely replacement of the filtration module. It is recommended to change the filtration module once every 3 months. 1. Shut off the water supply and relieve excess pressure before starting installation.
  • Page 15: Gross Prefiltration Module Installation (Optional)

    5.3. Gross prefiltration module installation (OPTIONAL) The pre-filter needs no specific servicing during its service life, except the timely replacement of the filtration module. It is recommended to change the filtration module once every 3 months 1. Shut off the water supply and relieve excess pressure before starting installation.
  • Page 16: Controller

    6. Controller 6.1. Controller’s description Controller with control panel and LED screen is designed to control the operation of RO system. It is controlled by buttons “Select”, “Clear” and “Flush”, and has the following functions: 1. Activation of pump and concentrate drainage valve. 2.
  • Page 17: Controller's Operation

    6.2. Controller’s operation a. When the system is turned on, the flush process starts. The default flush duration is 30 seconds. The flush indicator is ON. After flushing, the system goes to standard mode. b. If the accumulation tank is empty, FULL indicator is off. If the accumulation tank is full, FULL indicator is on, and the PURIFY indicator is off.
  • Page 18: Alarms & Troubleshooting

    7. Alarms & Troubleshooting Possible reason Solution Alarm / Trouble Low feed pressure / No feed Check feed pressure and feed SOURCE indicator is ON water water flow with sound signal Prefilter cartrdiges are clogged Replace prefilter cartridge The system is in operation Turn off the system for 15-20 mode for too long minutes.
  • Page 19: Maintenance

    8. Maintenance 8.1. General Recommendations 1. It is recommended to replace the pre-filter cartridge once every 3 months, or if the pressure is too low. 2. The RO membranes (MV-01) and pressure pump (P-01) are recommended to be replaced once a year.
  • Page 20: Service And Warranty

    Aquaphor warrants that the Aquaphor water filtration system shall be free from defects in material and workman ship under normal use and service. The reverse osmosis system APRO 100 / APRO 100 PRO – Two Year Warranty from the date of purchase. This does not apply, however, to consumable filters.
  • Page 21: Replacement Equipment List

    216592 LPS-01 Low pressure switch ¼” 522349 XV-01 Feed valve ¼” 519601 P-01 Feed pump 3/8” 208724 (APRO 100), 521628 (APRO 100 PRO) MV-01 Membrane housing 521922 CV-02 Check valve ¼” 201614 CV-04 Check valve ¼” 201614 RV-01 Regulating Valve ¼”...