E.

HEX6 TECHNICAL DATA

E.1     60 Hz Electric Heaters
Model
HEX6-208160-030
HEX6-208160-050
HEX6-208160-075
HEX6-208160-100*
HEX6-208360-030
HEX6-208360-050
HEX6-208360-075
HEX6-208360-100
HEX6-208360-150
HEX6-240160-030
HEX6-240160-050
HEX6-240160-075
HEX6-240160-100
HEX6-240160-150*
HEX6-240360-030
HEX6-240360-050
HEX6-240360-075
HEX6-240360-100
HEX6-240360-150
HEX6-480160-030 **
HEX6-480160-050 **
HEX6-480160-075 **
HEX6-480160-100 **
HEX6-480160-150 **
HEX6-480160-200 **
HEX6-480360-030
HEX6-480360-050
HEX6-480360-075
HEX6-480360-100
HEX6-480360-150
HEX6-480360-200
HEX6-480360-250
HEX6-480360-300
HEX6-480360-350
HEX6-600360-030
HEX6-600360-050
HEX6-600360-075
HEX6-600360-100
HEX6-600360-150
HEX6-600360-200
HEX6-600360-250
HEX6-600360-300
HEX6-600360-350
Notes
* Exceeds the 48 amp circuit limit of NEC 424-
22. DS not available for these units.
**480V: 1-phase units are certified for Class 
I, Div. 1, Group D and Class II, Div. 1 Groups
F & G. Heater rated for -20°C to +40°C.
Special Order.
12 12
C
V
kW
3.0
4.1
2700
5.0
4.1
4700
1
7.5
4.1
7200
10.0
4.1
9690
208
2.3
2700
3.0
5.0
2.3
4700
7.5
3
2.3
7200
10.0
2.3
9700
15
2.3
14400
4.1
2700
3.0
5.0
4.1
4700
7.5
1
4.1
7200
10.0
4.1
9700
15.0
4.1
14400
240
3.0
2.4
2700
5.0
2.4
4700
7.5
3
2.4
7200
2.4
9700
10.0
15.0
2.4
14400
3.0
0.8
2700
5.0
0.8
4700
0.8
7200
7.5
1
10.0
0.8
9700
15.0
0.8
14400
20.0
0.8
19400
1.2
2700
3.0
480
5.0
1.2
4700
7.5
1.2
7200
10.0
1.2
9700
1.2
14400
15.0
20.0
1.2
19400
25.0
1.2
24200
30.0
1.2
29200
35.0
1.2
34200
3
3.0
0.7
2700
5.0
0.7
4700
7.5
0.7
7200
10.0
0.7
9700
15.0
0.7
14400
600
20.0
0.7
19400
25.0
0.7
24200
30.0
0.7
29200
35.0
0.7
34200
1.
Minimum conductor size for 86˚F (30˚C)
ambient. Derate conductor for ambient
temperature. Use minimum 194˚F (90˚C)
insulation.
2.
Heater is functioning normally if at rated
voltage the amp draw is within 10% of the
value in this table.
3.
Operation at lower voltages will result in
reduced heat output and amp draw.
4.
Add "T" to model number when adding a
built-in thermostat.
US
W
A
A
AWG
18.5
23.2
10
28.1
35.2
8
40.2
50.2
6
52.2
65.2
6
10.6
13.3
14
16.2
20.2
10
23.1
28.9
10
30.1
37.6
8
44.0
55.0
6
16.6
20.8
10
24.9
31.2
8
35.4
44.2
8
45.8
57.2
6
66.6
83.3
4
9.6
12.0
14
14.4
18.1
12
20.5
25.6
10
26.5
33.1
8
38.5
48.2
8
7.1
8.8
14
11.2
14.0
14
16.4
20.5
10
21.6
27.0
10
32.1
40.1
8
42.5
53.1
6
4.8
6.0
14
7.2
9.0
14
10.2
12.8
14
13.2
16.6
12
19.3
24.1
10
25.3
31.6
8
31.3
39.1
8
37.3
46.7
8
43.3
54.2
6
3.6
4.5
14
5.5
6.9
14
7.9
9.9
14
10.3
12.9
14
15.2
18.9
12
20.0
25.0
10
24.8
31.0
8
29.6
37.0
8
34.4
43.0
8
Temperature
Rise
A
°F
°C
25
19.0
10.5
12116
40
31.6
17.6
12117
60
27.9
15.5
12118
70
37.2
20.7
12119
15
11.2
6.2
12116
25
18.6
10.3
12117
30
27.9
15.5
12118
40
37.2
20.7
12119
60
27.1
15.1
12120
25
19.0
10.5
12122
35
31.6
17.6
12123
45
27.9
15.5
12124
60
37.2
20.7
12125
90
27.1
15.1
12126
15
19.0
10.5
12122
20
31.6
17.6
12123
30
27.9
15.5
12124
35
37.2
20.7
12125
50
27.1
15.1
12126
10
19.0
10.5
12129
15
31.6
17.6
12130
25
27.9
15.5
12131
30
37.2
20.7
12132
45
27.1
15.1
12133
60
36.1
20.1
12134
10
19.0
10.5
12129
10
31.6
17.6
12130
15
27.9
15.5
12131
20
37.2
20.7
12132
25
27.1
15.1
12133
35
36.1
20.1
12134
40
22.0
12.2
12135
50
26.4
14.6
12136
60
30.7
17.1
12137
10
19.0
10.5
12138
10
31.6
17.6
12139
15
27.9
15.5
12140
15
18.1
20.7
12141
20
27.1
15.1
12142
30
36.1
20.1
12143
35
45.2
25.1
12144
40
26.4
14.6
12145
45
30.7
17.1
12146
5.
Add "D" to model number when adding a
built-in disconnect switch.
6.
Add "U" to model number for units with
continuous fan option.
7.
Add "A" to model number for units with
stainless steel cabinet.
8.
Add "L" to model number for large box
option.
9.
Add "P" to model number when adding a
built-in pilot light.
13847

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEX6 Series and is the answer not in the manual?

Questions and answers

Table of Contents