Page 1
BA230 • This product has been tested in Gi.Bi.Di. verifying the perfect correspondence of the characteristics to the current directive. • Gi.Bi.Di. S.r.l. reserves the right to modify the technical data without prior notice depending on the product development. PLEASE READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. BA230 BA230 - (AS05040) Electronic control unit...
Page 2
BA230 BA230/AS05040 Control unit 230 VAC electronic control unit for automation of one or two motors for swing gates, sliding gates, Type overhead doors and barriers Power supply 230VAC, single-phase, 50/60 Hz No. of motors 1 or 2 Motor power supply 230 Vac Flashlight 230Vac 40W max...
BA230 INSTALLATION Use glands adequate to ensure proper mechanical connection of cable and maintain the box protection degree IP55. (FIG. 2) INSTALLATION WARNINGS • Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of 10A upstream of the system.
BA230 Closing limit switch input - motor 2 (N.C.). FCCM2 If not used, disable during programming by enabling the C10 menu. PHOTOCELL 2 input (N.C.). If not used, jumper with terminal 31 Operation: Input active during both opening and closing. If intercepted, it immediately stops the motion and holds it stopped until the photocell is freed.
Page 6
BA230 INSTALLER CODE INSERTION To access programming, simultaneously press the OK and ESC _ _ _ _ buttons for 3 seconds. _ _ _ _ _ _ _ _ The letters P A S S appear on the display. Press the OK button to go to step 3. PASS Press the ESC button to exit and return to step 1.
BA230 The last digit blinks. Use the + or - buttons to select the fourth digit of the installer code. 4680 Once you have arrived at the desired digit, confirm with the OK button and go to step 7. The installer code is now complete: if it is correct, go to step 8. If the installer code is not correct, return to step 2.
Page 8
BA230 At this point, use the + and - buttons to display the other submenus of the menu A and follow the same procedure as before. Use the ESC button to return to the higher level (menu A, C, F, Access the submenu H1 to view the settings of a numerical value.
Page 9
BA230 The third digit blinks. Use the + or - buttons to modify the value of this digit. Confirm with the OK button and go to step 16. 0100 The fourth digit blinks. Use the + or - buttons to modify the value of this digit. Confirm with the OK button and go to step 17.
Page 10
BA230 MENU A: SYSTEM CONFIGURATION AND OPERATING LOGIC SELECTION Menu Function Status Description Configures the system for a swing gate. SWING GATE Configures the system for an overhead door or barrier. OVERHEAD DOOR/ BARRIER Configures the system for a sliding gate. SLIDING GATE Configures the system for 1 motor.
Page 11
BA230 MENU C: FUNCTION SELECTION Menu Function Status Description Enables automatic closing. Also see menu H9. AUTOMATIC CLOSING Disables automatic closing. Enables the fast closing function. Operation: Active only on photocell 1. Reduces the pause time to 3 seconds following interception and subsequent FAST CLOSING freeing of the photocells.
Page 12
BA230 MENU F: FORCE AND SPEED ADJUSTMENTS Menu Function Description Adjusts the thrust of motor 1. 0001 = minimum force MOTOR 1 FORCE 0010 = maximum force NB. HYDRAULIC OPERATORS, SET MAXIMUM VALUE Adjusts the thrust of motor 1 during deceleration DECELERATION 0001 = minimum force FORCE MOTOR 1...
Page 13
BA230 TIME LEARNING PROCEDURE To access this procedure, select the menu C21. CAUTION: Always start with the gate fully closed. The times are programmed by means of successive start pulses. During the time self-learning phase, C21 blinks continuously on the display. During the time self-learning phase, motion always occurs at a non-decelerated speed.
BA230 DEFAULT SETTINGS • Parameters type A active: SWING GATE TYPE 2 MOTORS AUTOMATIC LOGIC • Parameters type C active: AUTOMATIC CLOSING ENABLED FAST CLOSING DISABLED PRE-FLASHING ENABLED SAFETY DEVICE TEST DISABLED LIMIT SWITCHES DISABLED DECELERATION DISABLED WATER HAMMER DISABLED FINAL CLOSING STROKE DISABLED HYDRAULIC LOCK RETENTION DISABLED ANTI-CRUSHING DISABLED (NOT IMPLEMENTED)
Page 15
BA230 FINAL CHECKS AND TESTING Before powering the control unit, run the following tests: 1 - Check the electrical connections: improper connection may be harmful to both the control unit and the operator. 2 - Check proper positioning of the limit switches. 3 - Check that the red LEDs of the normally closed contacts are on and that the green LEDs of the normally open contacts are off.