Bandini Industrie GiBiDi BA230 Instructions For Installations

Bandini Industrie GiBiDi BA230 Instructions For Installations

Electronic control unit
Hide thumbs Also See for GiBiDi BA230:

Advertisement

BA230
BA230 - (AS05040)
GI.BI.DI. S.r.l.
Via Abetone Brennero, 177/B
46025 Poggio Rusco (MN) - ITALY
Tel. +39.0386.52.20.11
Fax +39.0386.52.20.31
E-mail: comm@gibidi.com
Numero Verde: 800.290156
w w w . g i b i d i . c o m
UK
Electronic control unit
INSTRUCTIONS FOR INSTALLATIONS
UK
• This product has been tested in Gi.Bi.Di. verifying the perfect correspondence of the characteristics to the
current directive.
• Gi.Bi.Di. S.r.l. reserves the right to modify the technical data without prior notice depending on the product
development.
PLEASE READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION.
BA230

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GiBiDi BA230 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bandini Industrie GiBiDi BA230

  • Page 1 BA230 • This product has been tested in Gi.Bi.Di. verifying the perfect correspondence of the characteristics to the current directive. • Gi.Bi.Di. S.r.l. reserves the right to modify the technical data without prior notice depending on the product development. PLEASE READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. BA230 BA230 - (AS05040) Electronic control unit...
  • Page 2 BA230 BA230/AS05040 Control unit 230 VAC electronic control unit for automation of one or two motors for swing gates, sliding gates, Type overhead doors and barriers Power supply 230VAC, single-phase, 50/60 Hz No. of motors 1 or 2 Motor power supply 230 Vac Flashlight 230Vac 40W max...
  • Page 3: Installation Warnings

    BA230 INSTALLATION Use glands adequate to ensure proper mechanical connection of cable and maintain the box protection degree IP55. (FIG. 2) INSTALLATION WARNINGS • Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of 10A upstream of the system.
  • Page 4 BA230 ELECTRICAL CONNECTIONS: FASTONS Primary connection of 230 VAC transformer (black cables) CF1 CF3 Secondary connection of 14 VAC transformer (red cables) CF2 CF4 Secondary connection of 22 VAC transformer (blue cables) CF5 CF6 Motor 2 capacitor connection CF7 CF8 Motor 1 capacitor connection CF9 CF10 ELECTRICAL CONNECTIONS: TERMINAL BOARDS...
  • Page 5: Protection Fuses

    BA230 Closing limit switch input - motor 2 (N.C.). FCCM2 If not used, disable during programming by enabling the C10 menu. PHOTOCELL 2 input (N.C.). If not used, jumper with terminal 31 Operation: Input active during both opening and closing. If intercepted, it immediately stops the motion and holds it stopped until the photocell is freed.
  • Page 6 BA230 INSTALLER CODE INSERTION To access programming, simultaneously press the OK and ESC _ _ _ _ buttons for 3 seconds. _ _ _ _ _ _ _ _ The letters P A S S appear on the display. Press the OK button to go to step 3. PASS Press the ESC button to exit and return to step 1.
  • Page 7: Programming Example

    BA230 The last digit blinks. Use the + or - buttons to select the fourth digit of the installer code. 4680 Once you have arrived at the desired digit, confirm with the OK button and go to step 7. The installer code is now complete: if it is correct, go to step 8. If the installer code is not correct, return to step 2.
  • Page 8 BA230 At this point, use the + and - buttons to display the other submenus of the menu A and follow the same procedure as before. Use the ESC button to return to the higher level (menu A, C, F, Access the submenu H1 to view the settings of a numerical value.
  • Page 9 BA230 The third digit blinks. Use the + or - buttons to modify the value of this digit. Confirm with the OK button and go to step 16. 0100 The fourth digit blinks. Use the + or - buttons to modify the value of this digit. Confirm with the OK button and go to step 17.
  • Page 10 BA230 MENU A: SYSTEM CONFIGURATION AND OPERATING LOGIC SELECTION Menu Function Status Description Configures the system for a swing gate. SWING GATE Configures the system for an overhead door or barrier. OVERHEAD DOOR/ BARRIER Configures the system for a sliding gate. SLIDING GATE Configures the system for 1 motor.
  • Page 11 BA230 MENU C: FUNCTION SELECTION Menu Function Status Description Enables automatic closing. Also see menu H9. AUTOMATIC CLOSING Disables automatic closing. Enables the fast closing function. Operation: Active only on photocell 1. Reduces the pause time to 3 seconds following interception and subsequent FAST CLOSING freeing of the photocells.
  • Page 12 BA230 MENU F: FORCE AND SPEED ADJUSTMENTS Menu Function Description Adjusts the thrust of motor 1. 0001 = minimum force MOTOR 1 FORCE 0010 = maximum force NB. HYDRAULIC OPERATORS, SET MAXIMUM VALUE Adjusts the thrust of motor 1 during deceleration DECELERATION 0001 = minimum force FORCE MOTOR 1...
  • Page 13 BA230 TIME LEARNING PROCEDURE To access this procedure, select the menu C21. CAUTION: Always start with the gate fully closed. The times are programmed by means of successive start pulses. During the time self-learning phase, C21 blinks continuously on the display. During the time self-learning phase, motion always occurs at a non-decelerated speed.
  • Page 14: Default Settings

    BA230 DEFAULT SETTINGS • Parameters type A active: SWING GATE TYPE 2 MOTORS AUTOMATIC LOGIC • Parameters type C active: AUTOMATIC CLOSING ENABLED FAST CLOSING DISABLED PRE-FLASHING ENABLED SAFETY DEVICE TEST DISABLED LIMIT SWITCHES DISABLED DECELERATION DISABLED WATER HAMMER DISABLED FINAL CLOSING STROKE DISABLED HYDRAULIC LOCK RETENTION DISABLED ANTI-CRUSHING DISABLED (NOT IMPLEMENTED)
  • Page 15 BA230 FINAL CHECKS AND TESTING Before powering the control unit, run the following tests: 1 - Check the electrical connections: improper connection may be harmful to both the control unit and the operator. 2 - Check proper positioning of the limit switches. 3 - Check that the red LEDs of the normally closed contacts are on and that the green LEDs of the normally open contacts are off.
  • Page 16 BA230 CE Declaration of conformity The manufacturer: GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the products: ELECTRONIC CONTROL UNIT BA230 are in conformity with the following CEE Directives: • LVD Directive 2006/95/CE and subsequent amendments; •...