Download Print this page

Bandini Industrie GBD F4 PLUS Instructions For Installations

Electronic control unit

Advertisement

Quick Links

F4 PLUS
F4 PLUS (AS04180)
Apparecchiatura elettronica
ISTRUZIONI PER L'INSTALLAZIONE
Electronic control unit
INSTRUCTIONS FOR INSTALLATIONS
I
UK
F
E
D
P
NL
GR

Advertisement

loading

Summary of Contents for Bandini Industrie GBD F4 PLUS

  • Page 1 F4 PLUS F4 PLUS (AS04180) Apparecchiatura elettronica ISTRUZIONI PER L’INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS...
  • Page 2 F4 PLUS • Questo prodotto è stato collaudato in GI.BI.DI. verificando la perfetta corrispondenza delle caratteristiche alle direttive vigenti. • La GI.BI.DI. S.r.l. si riserva la facoltà di modificare i dati tecnici senza avviso, in funzione dell'evoluzione del prodotto. LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA DI PROCEDERE ALL’INSTALLAZIONE. •...
  • Page 3 F4 PLUS 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 24 VAC FOTO START STOP S.PED F 0.16A V2 LAV V3 SFAS V4 PAUSA 1 2 3 4 5 6 7 8 9 10 LEARN RESET DIP1 FOTO STOP...
  • Page 4: Installation

    F4 PLUS F4 PLUS/AS04180 Control unit 230 VAC electronic control unit for automation of one or two motors for swing gates, sliding gates, Type overhead doors and barriers Power supply 220 / 230VAC, single-phase, 50/60 Hz Motor power supply 220 / 230 Vdc 1 o 2 No.
  • Page 5 F4 PLUS INSTALLATION WARNINGS • Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of 10A upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3 mm. •...
  • Page 6 F4 PLUS ELECTRICAL CONNECTIONS: TERMINAL BOARDS Output - OPENS motor 1 LIMIT SWITCH input-opens motor 2 (NC) (motor to be used for pedestrian gate) * COMMON output - motor 1 LIMIT SWITCH input-closes motor 1(NC) (motor to be used for pedestrian gate) * Output - CLOSES motor 1 LIMIT SWITCH input-opens motor 1 (NC) (motor to be used for pedestrian gate) *...
  • Page 7 F4 PLUS PROGRAMMING FUNCTIONS (DIP SWITCH) When the photocell is intercepted, both during opening and closing, the gate motion is locked until the photocell is freed. Subsequently, there is always an opening phase. DIP1 The photocell stops and immediately inverts the motion of the gate during the closing phase, while during opening it is uninfluential.
  • Page 8 F4 PLUS DEFAULT SETTINGS (DIP SWITCH) DIP SWITCHES 1, 2, 3, 9, 10 OFF; DIP SWITCHES 4, 5, 6, 7, 8 ON TRIMMER ADJUSTMENT There are 4 trimmers (V1-V2-V3-V4) on the F4PLUS control unit to adjust the following: TRIMMER FUNCTION DESCRIPTION Turned clockwise it adjusts the motor torque from 40% to 98%.
  • Page 9: Troubleshooting

    F4 PLUS TROUBLESHOOTING Before any installation or maintenance operation, ensure that the power supply has been disconnected.!! FAULT POSSIBLE CAUSES and SOLUTIONS Red 24 Vac LED off Check the 230 Vac power supply and the relevant fuse F1(5A) The operator does not Check that the red LEDs are on (except the LED of the limit switch active at open or reclose that moment) and the yellow ones off.
  • Page 10 F4 PLUS CE Declaration of conformity The manufacturer: GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the products: ELECTRONIC CONTROL UNIT F4 PLUS are in conformity with the following CEE Directives: • LVD Directive 2006/95/CE and subsequent amendments; •...
  • Page 11 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: comm@gibidi.com Numero Verde: 800.290156 w w w . g i b i d i . c o m...

This manual is also suitable for: