press to the mount assembly bottom until it locks into place with a
click (see Figure 2-7).

2-8 OPERATING PROCEDuRES

This section contains operating procedures for using the PVS-7 as
a hand-held, head mounted or helmet mounted goggle. Prior to op-
erating the goggle, ensure that all the steps in paragraph 2-6 have
been read and performed.
A. Head Mounted Operation. Perform the following procedures
for head mounted operation.
CAUTION
OPERATE THE PVS-7 ONLY UNDER DARKENED CONDITIONS
OR USE THE LENS CAP TO COVER THE OBJECTIVE LENS FOR
DAYLIGHT CONDITIONS.
NOTE
Proper objective focus cannot be obtained while the objective
lens cap with pinhole is covering the objective lens. Proper objec-
tive focus must be done in the dark with the objective lens cover
removed.
1. Ensure that the batteries are installed per paragraph 2-6, B.
2. Don the head mount per instructions in paragraph 2-6, I.
NOTE
Paragraphs 2-6, J, 2-6, K and 2-6, L provide additional information
required when installing the head mount with a protective mask,
PASGT or M1 helmet.
To make it easier to align the goggle, eyecups and diopter eyepiec-
es to the eyes, depress the socket-release button (See Figure 2-4)
and slide the head mount socket all the way forward before attach-
ing the goggles.
3. Align the PVS-7 's latch (Figure 2-1) to the head mount socket
(See Figure 2-4). Press and hold down the latch lever while install-
ing the goggle into the head mount socket. Release the latch when
the goggle is fully engaged in the socket.