ED5200(S)N & ED5600N Series with Aperio™ Technology
Exit Devices - Includes Rim and Mortise
Installation Instructions
7
Mortise Exit Installation Instructions, continued
f
Harness Connections (Figure 21)
1. Connect motor harness adapter to
chassis harness connector.
2. Connect rail assembly harness
adapter to chassis harness
connector.
g
Install Head Cover
1. Lay device wire harnesses
across 3/4" hole. (Figure 22)
2. Attach head cover using two
(2) #8-32 flat head screws.
(Figure 23).
3. Take care not to pinch wires
between cover and door.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2022, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved.
Reproduction in whole or in part without the express written permission of ASSA ABLOY Access
and Egress Hardware Group, Inc. is prohibited.
Figure 22
Chassis
Harness
Motor Harness
Adapter
Figure 21
Use 3/4" hole to
tuck trim and
device wire
harness under
head cover
14
Rail Assembly
Harness
Adapter
Figure 23