EN
1 Scope of delivery
For professional installation of the filter system the following parts are required:
Filter cartridge (1) with hygienic cap and male thread for screwing into the filter head (2).
Filter head (2) with female thread for mounting the filter cartridge (1), suitable for all filter
cartridge sizes with installation label. An Aquastop and two non return valves (inlet and outlet)
are installed in the filter head.
Bracket (3) for mounting the filter cartridge.
The filter cartridge has to be ordered separately from the filter head. The bracket is included in
the scope of delivery of the filter head.
2 Technical Data
2.1 Dimensions und weights
Total height without bracket, max. A mm (inch)
Total height with bracket
Connection height
Distance from floor
Installation length
Filter cartridge Ø
Weight of dry filter cartridge, approx.
Weight of wet filter cartridge, approx.
2.2 Operating conditions
Connection thread (intake/outlet)
Nominal flow
Working pressure range
Intake water pressure
Pressure loss at 30 L/h (8 US gallons/h)¹
Pressure loss at 60 L/h (16 US gallons/h)¹
Pressure loss at 180 L/h (48 US gallons/h)¹
Water temperature, min.–max.
Ambient temperature, min.–max.
Ambient temperature during transportation/
storage, min.–max.
Bed volume
Operating position
Minimum flushing volume
¹with a 1.5 m (59.06 inch) hose DN8 fitted to both the intake and outlet.
Typical capacity at 8 – 14 °dGH²,*
Chlorine reduction according to 5.5.2 EN 14898:2006
Reduction (influent challenge concentration 2.0 mg/l)³
²The actual capacities in operation can be higher or lower than the capacities stated in the table. The capacities depend on the quality of the input water,
the flow rate, the intake water pressure and the flow continuity. The general hardness reduction is reached in accordance with Section 5.5.5 EN 14898:2006
for the stated capacities.
³The concentration of chlorine in water entering the system was reduced to a concentration less than or equal to the permissible limit for water laving the
system, as specified in NSF/ANSI 42. While testing was performed under standard laboratory conditions, actual perfomance of the system may vary.*
T1
Typical filter capacities and bypass settings are listed in Chapter 9.
11
M200
360 (14
B mm (inch)
385 (15
C mm (inch)
306 (12
D mm (inch)
65 (2
E mm (inch)
125 (4
F mm (inch)
88 (3
kg (lb)
0.9 (2.0)
kg (lb)
1.5 (3.3)
L/h (US gal/h)
bar (psi)
bar (psi)
bar (psi)
bar (psi)
bar (psi)
°C (°F)
°C (°F)
°C (°F)
L (US gal)
L (US gal)
L (US gal)
Category
%
M300
/
)
420 (16
/
)
3
9
16
16
/
)
445 (17
/
)
3
1
16
2
/
)
336 (14
/
)
1
7
16
16
/
)
65 (2
/
)
9
9
16
16
/
)
125 (4
/
)
15
15
16
16
/
)
110 (4
/
)
7
5
16
16
2.1 (4.6)
3.2 (7.1)
M200
M300
/
" (BSP male)
3
8
180 (48)
2 – 8 (29 - 116)
> 1.2 (> 17.4)
0.10 (1.5)
0.10 (1.5)
0.15 (2.2)
0.15 (2.2)
0.60 (8.7)
0.60 (8.7)
+4 to +30 (+39 to +86)
+4 to +40 (+39 to +104)
-20 to +40 (-4 to +104)
0.70 (0.2)
1.50 (0.4)
horizontal or vertical
2 (0.5)
3 (0.8)
M200
M300
1140 (301)
2860 (756)
> 50 %
M400
475 (18
/
)
11
16
500 (19
/
)
11
16
421 (16
/
)
9
16
65 (2
/
)
9
16
125 (4
/
)
15
16
130 (5
/
)
1
8
2.4 (5.3)
4.2 (9.3)
M400
0.05 (0.7)
2
0.20 (2.9)
0.50 (7.3)
2.00 (0.5)
5 (1.3)
M400
4280 (1131)
1
1