DUAL MEDIUM INTENSITY LED/STROBE
4.0
TROUBLESHOOTING
Much of the troubleshooting of this system will consist of correcting a "beacon out"
situation. There may also be a failure mode where the flashtube is still flashing, but at the
wrong rate or the wrong intensity.
You must study and understand the safety messages and the theory of operation before
attempting any service on this system. Servicing this system must be done by qualified
personnel only.
***W A R N I N G – H I G H – V O L T A G E***
THIS SYSTEM OPERATES AT HIGH VOLTAGE LEVELS THAT COULD BE LETHAL
TO SERVICE PERSONNEL. ALL INSTALLATION AND MAINTENANCE WORK MUST
BE DONE BY QUALIFIED SERVICE PERSONNEL. READ AND UNDERSTAND THE
THEORY OF OPERATION AND ITS SAFETY MESSAGES BEFORE ATTEMPTING
INSTALLATION OF THIS SYSTEM. DO NOT ATTEMPT TO DEFEAT THE INTERNAL
SAFETY DEVICES.
4.1
TOOL REQUIREMENTS
In order to be prepared to troubleshoot or repair this system, a minimum amount of
tools and equipment will be required. A recommendation list includes:
1)
1)
1)
M.E-2018.E-1DBSL
11-11-08 REV 1-19-18
MODEL E-1DBSL
5/16 Flat Electrician's Screwdriver
Nut Driver or Socket Set
VOM with 600V AC / 1,000V DC range and a 40M ohm scale