Furuno MU-190 Operator's Manual
Furuno MU-190 Operator's Manual

Furuno MU-190 Operator's Manual

Marine display
Hide thumbs Also See for MU-190:

Advertisement

Quick Links

OPERATOR'S MANUAL
MARINE DISPLAY
MU-190/MU-192
Model
(Product Name: MONITOR UNIT)
www.furuno.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MU-190 and is the answer not in the manual?

Questions and answers

Summary of Contents for Furuno MU-190

  • Page 1 OPERATOR'S MANUAL MARINE DISPLAY MU-190/MU-192 Model (Product Name: MONITOR UNIT) www.furuno.com...
  • Page 2 ・ FURUNO Authorized Distributor/Dealer : MAY 2011 : AUG. 6, 2024 Printed in Japan Pub. No. OMC-44670-J ( TEHI ) MU-190/MU-192 00017448918...
  • Page 3 How to discard a used battery Some FURUNO products have a battery(ies). To see if your product has a battery, see the chapter on Maintenance. If a battery is used, tape the + and - terminals of the battery before disposal to pre- vent fire, heat generation caused by short circuit.
  • Page 4 Continued use of the equipment can cause Do not place any object near the fire or electrical shock. Contact a FURUNO exhaust or intake vent. agent for service. Fire may result. Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire.
  • Page 5 AC power supply to prevent electrical shock. Warning Labels Warning labels are attached to the equipment. Do not remove the labels. If a label is missing or damaged, contact a FURUNO agent or dealer about replacement. Name: Warning Label 1 Name:...
  • Page 6: Table Of Contents

    3.4 How to Select the Source for Main Picture ..............22 3.5 How to Display the PIP Window.................. 22 3.6 SYSTEM Menu ......................23 3.6.1 How to set the auto dimmer (available MU-190 only).......... 23 3.6.2 How to clear the memory..................23 MAINTENANCE ......................24 4.1 Maintenance........................
  • Page 7: Foreword

    FCR-21x7 series, FCR-21x9 series, FAR-3xxx series or FAR-2xx8 series lock the key operation (see paragraph 3.2.2) after confirming the program numbers. *: To connect the MU-190 to the FMD-3xxx, the program version for the APR program must be 2651020-01.02 or higher.
  • Page 8: System Configuration

    CCD camera, DVD recorder, etc. RS-485 FMD-3xxx, FCR-21x9, FAR-3xxx, FAR-2xx8, etc. RS-232C FEA-2107, FCR-21x7, etc. MONITOR UNIT MU-190/MU-192 Environmental category 100-230 VAC MU-190/MU-192: Protected from the weather Example: Connectable equipment Equipment Resolution Signal FCV-1200L/1200LM VGA* Analog RGB, via IF-8000 FSV-24/24S SXGA...
  • Page 9: Equipment Lists

    EQUIPMENT LISTS Standard supply Name Type Code No. Remarks Monitor Unit MU-190 MU-192 Installation CP26-01600 000-019-210 1 set For MU-190 Materials CP26-02700 000-043-856 1 set For MU-192 Accessories FP26-00401 001-175-940 1 set LCD Cleaning Cloth (19-028-3125-6, (MU-190) Code No.: 100-360-676-10)
  • Page 10 Remarks Hood (19) Assem- OP26-24 001-139-370 For MU-190 OP26-51 001-661-360 For MU-192 Monitor OP26-22 001-139-320 For flush mount (MU-190) Replacement Kit OP26-23 001-139-360 For tabletop mount (MU-190) OP26-26 001-139-390 For hood mount (MU-190) OP26-49 001-661-300 For flush mount (MU-192) OP26-50...
  • Page 11: Mounting, Wiring

    • Tabletop mount (option, hood-mountable) • Flush mount a series side by side, fixed at rear Note 1: Illustrations in this manual are primarily for the MU-190. The layout may differ slightly from that of the MU-192. Note 2: The face of the LCD is made of glass. Handle it with care.
  • Page 12: Flush Mount, Fixed At Front

    1. MOUNTING, WIRING Flush Mount, Fixed at Front Flush mount, fix at front is the standard installation method. 1. Use the flush mounting template (supplied) to make a cutout in the mounting location. 2. Attach the flush mounting sponges H19 and V19 to the back of the monitor unit in the order shown in the figure at right.
  • Page 13: Flush Mount, Fixed At Front, With Hood

    Flush Mount, Fixed at Front, with Hood The flush mount, fixed at front method allows you to attach a hood (19) assembly OP26-24 (op- tion, for MU-190) or OP26-51 (option, for MU-192) to the monitor unit. Hood (19) assembly OP26-24 (Code No.: 001-139-370)
  • Page 14 1. MOUNTING, WIRING Hood (19) assembly OP26-51 (Code No.: 001-661-360) Name Type Code No. Hood (19) Assembly OP26-6-1 001-080-970 Knob M4 03-163-2303 100-343-602-10 Hood Fixing Plate (19) 26-012-1016-1 100-449-811-10 Binding Head Screw M38 000-172-166-10 1. Use the flush mounting template (supplied) to make a cutout in the mounting location. 2.
  • Page 15: Flush Mount, Fixed At Rear

    1. MOUNTING, WIRING 6. Press and rub folds on the hood with your hands to make creases clearly. The degree of creases should be within 90° when the hood is opened. Hood Correct Incorrect, insufficient Press and move your hands to upward and downward several times.
  • Page 16 1. MOUNTING, WIRING 2. Attach the flush mount- ing sponges H 19 (2 mm) and V 19 (2 mm) to the back of the monitor unit in the order shown Flush Mounting Sponge Flush Mounting Sponge in the figure at right. H 19 (2 mm) for top and V 19 (2 mm) for left and bottom...
  • Page 17: Flush Mount, Fixed At Rear, With Hood

    1. MOUNTING, WIRING 9. Fasten the wing nuts tightly. Wing Bolt Wing Nut Fixing Plate Protector for Screw Mounting Panel Flush Mount, Fixed at Rear, with Hood The flush mount, fixed at rear method allows you to attach a hood assembly OP26-6 to the mon- itor unit.
  • Page 18 1. MOUNTING, WIRING 3. Attach the F-mount hood packing 19 to the top and bottom brims. Then, attach the flush mounting sponge V 19 to the right and left brims of the monitor unit from the rear side. F-Mount Hood Packing 19 for Flush Mounting top and bottom...
  • Page 19: Tabletop Mount

    1. MOUNTING, WIRING Tabletop Mount You can fix the monitor unit to a tabletop, using the optional bracket assembly OP26-5 (for MU- 190) or OP26-48 (for MU-192). Bracket Assembly OP26-5 (Code No.: 000-016-270) Name Type Code No. Mounting Bracket (19) OP26-5-1 001-080-510 Bracket Support w/Knobs...
  • Page 20 1. MOUNTING, WIRING 3. Attach the bracket support to the rear of the monitor unit with the binding head screws (9 pcs.). Bracket Support w/Knobs Binding Head Screw (9 places) Binding Head Screw Rear view 4. Connect all cables at the back of the monitor unit. See section 1.8. 5.
  • Page 21: Flush Mount A Series Side By Side

    1. MOUNTING, WIRING Flush Mount a Series Side by Side You can flush mount two or three monitor units side by side, using the optional flush mount kit OP26-13 for two monitor units or OP26-14 for three monitor units (see page vii). 1.
  • Page 22: Wiring

    Cut the connector of the power cable (15-565, supplied on the Local supply MU-201CE). Attach a crimp-on lug (supplied on the MU-190/192) to each cable core then connect the cables as in the figure at right. Cable Length: 60 mm...
  • Page 23: Adjustments

    ADJUSTMENTS Adjust the MU-190/192 according to the equipment connected. Note: Sections 2.2, 2.3 and 2.4 are for Non-SOLAS. Installation Settings The [INSTALLATION SETTING] menu appears only when the power is turned on for the first time after installation. Menu INSTALLATION SETTING...
  • Page 24 2. ADJUSTMENTS at the factory to ON to control the power on/off from the equipment connected via DVI signal. Slide switch ON (Default setting) Slide switch ON (Default setting) RGB port DVI port Bottom rear of the monitor unit 1. Press the  or  key to select the menu item to adjust on the [INSTALLATION SETTING] menu.
  • Page 25: Rgb/Dvi Setting (For Non-Solas)

    2. ADJUSTMENTS Menu item Function Setting [KEY LOCK] Select whether to lock the key operation or not (see [OFF], [ON] paragraph 3.2.2). [OFF]: Do not lock the key operation. [ON]: Lock the key operation. [SAVE AND EXIT] Select whether to save the settings or not. [NO], [YES] [NO]: Cancel the settings.
  • Page 26 2. ADJUSTMENTS [RGB], [DVI1/2] menu descriptions Menu item Function Setting H_SIZE (Only for Adjust the image size horizontally. Depending on in- Horizontal size:  (narrow),  (wide) RGB menu) put signal V_SIZE (Only for Adjust the image size vertically. Vertical size:  (narrow),  (wide) RGB menu) PHASE** (Only Adjust the sample timing so that the flicker disappears and...
  • Page 27: Video Composite Signal Setting (For Non-Solas)

    2. ADJUSTMENTS Video Composite Signal Setting (For Non-SO- LAS) You can adjust the VIDEO signal from the VIDEO port. The VIDEO signal is also displayed in the PIP window (see section 3.5). 1. Select the signal to adjust at the DISP selection window. 2.
  • Page 28: The Menu Window Setting (For Non-Solas)

    2. ADJUSTMENTS The Menu Window Setting (For Non-SOLAS) 2.4.1 How to adjust the menu window You can adjust the position and transparency of the menu window on the [OSD] (On Screen Dis- play) menu. 1. Press the MENU key to show the menu. 2.
  • Page 29: How To Change The Signal Name

    2. ADJUSTMENTS 2.4.2 How to change the signal name You can change the signal name ([RGB], [DVI1/2] or [VIDEO]) to a name (ex. the equipment name) which is easy to understand. The name is shown in the DISP selection window and the indication shown at the upper right of the screen (see section 3.4).
  • Page 30: Operation

    Night) of those models. When you connect the monitor unit to the equipment other than FMD- 3xxx, FAR-21x7, FEA-2107, FCR-21x7, FCR-21x9, FAR-3xxx or FAR-2xx8, the control is done from the MU-190/192. If the keys of MU-190/192 are not illuminated, provide external, dimmable illumination, e.g. gooseneck lamp.
  • Page 31: Unlock The Key Operation

    Note 2: When you connect the cables to both DVI-D1 and DVI-D2 ports, turn off the power of both equipment to turn off the monitor unit. Slide switch “OFF” 1. Press the /BRILL key to turn on the MU-190/192. 2. Press and hold the /BRILL key for three seconds to SHUT DOWN turn off the monitor unit.
  • Page 32: How To Select The Source For Main Picture

    3. OPERATION manual. For Non-SOLAS: Press the /BRILL key repeatedly to adjust the brilliance. How to Select the Source for Main Picture Select the signal to display on the entire screen as follows: 1. Press the DISP key to show the DISP selection window. The window shows the signal names as you customized them at paragraph 2.4.2.
  • Page 33: System Menu

    The [SYSTEM] menu controls the brilliance, clears the memory and shows signal status and pro- gram number. 3.6.1 How to set the auto dimmer (available MU-190 only) The auto dimmer feature automatically adjusts the brilliance according to the am- DVI1...
  • Page 34: Maintenance

    When the fan does not rotate sufficiently, the message "Fan re- placement" is shown. Turn off the power and call for service to request replacement of the fan. Item Life Type Code Number FAN1 (MU-190) Approximately 40,000 hours MFB52A-12HA-001 000-172-023-10...
  • Page 35: Troubleshooting

    LQ0DDB0094, 26S0048 (Fan motor assembly (FAN4), Wind direction: upward) OZP-120-12/15-J06 or UZP-120-12-J0L2 LQ190E1LX51F, 26S100790 (LCD) 26P0023 ESSIP33×-××/ ESSIP70×-×× 26P0013 (AD board, ×-××: Revision number) MU-190 Parts Location 109P0612H755 (FAN1/FAN2) UZP-120-12-J0L2 P1900SXF1MBAA (LCD) 26P0023 ESSIP70×-2× (AD board, 26P0013 ×-2×: Revision number)
  • Page 36 4. MAINTENANCE Parts list ELECTRICAL PARTS Model MU-190 Unit Monitor unit MU-190 PRINTED CIRCUIT BOARD Code No. OZP-120-12/15-J06 26P0023 (PSW board) ESSIP33×-××/ESSIP70×-×× (AD board, ×-××: Revision number) 26P0013 Code No. LQ190E1LX51, 26S0027 Code No. MFB52A-12HA-001, 26S0028 (FAN1) LQ0DDB0094, 26S0048 (FAN4)
  • Page 37: Appx. 1 Jis Cable Guide

    EX: TTYCYSLA - 4 MPYC - 4 # of cores Designation type Designation type # of twisted pairs TTYCSLA-4 The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Cable Core Cable Core Diameter Type...
  • Page 38: Appx. 2 Abbreviations

    Brilliance Charge-Coupled Device DISP Display Digital Versatile Disk Digital Visual Interface ECDIS Electronic Chart Display and Information System Type of FURUNO radar Type of FURUNO ECDIS FPGA Field-Programmable Gate Array Left Liquid Crystal Display NTSC National Television System Committee On Screen Display...
  • Page 39: Specifications

    FURUNO MU-190 SPECIFICATIONS OF MONITOR UNIT MU-190 GENERAL Display 19-inch color LCD Effective area 376.32 x 301.06 mm Resolution SXGA (1280 x 1024 pixel) Pixel pitch 0.294 mm (Horizon/Vertical) Brightness 450 cd/m typical Contrast 900: 1 View angle 160° (up/down, left/right 80° or more)
  • Page 40 400 cd/m typical View angle 85° or more (up/down, left/right) Visible distance 1.02 m (for using as a display of FURUNO radar/ECDIS) Input signal RGB analog 1 port, non-interlace, video 0.7 Vp-p, sync. TTL level DVI-D 2 ports, DVI-standard, VESA DDC2B Composite 1 port, NTSC/PAL standard, video 0.7 Vp-p...
  • Page 41 C C ODE NO. 001‑116‑250‑00 26AH‑X‑9401 ‑4 TYPE CP26‑01601 工事材料表 MU‑190 INSTALLATION MATERIALS 番 号 名  称  型名/規格 数量 略  図 用途/備考 Q'TY  NO.  NAME OUTLINE DESCRIPTIONS REMARKS FマウントスポンジV19 26‑005‑3124‑0 FLUSH MOUNTING SPONGE  V 19 CODE  100‑351‑560‑10 化粧パネル19 26‑007‑1124‑3 MASKING PANEL FOR 19"  CODE  100‑363‑463‑10 FマウントスポンジH19 26‑007‑1127‑0 FLUSH MOUNTING SPONGE  CODE  100‑363‑240‑10 +トラスタッピンネジ 1シュ 5X20 SUS304 SELF‑TAPPING SCREW CODE ...