D-Link DGS-3100 User Manual page 47

Dgs-3100 series gigabit stackable managed switch
Hide thumbs Also See for DGS-3100:
Table of Contents

Advertisement

DGS-3100 Series Gigabit Stackable Managed Switch User Manual
The Time Settings Page contains the following fields:
Status
Field
Time Source
Current Time
SNTP Settings Section
Field
SNTP First Server
SNTP Second Server
SNTP Poll Interval in Seconds
Set Current Time
Field
Time Setting
Time in HH MM SS
2. Select a time source in the Time Source field.
3. Define the fields.
4. Click
35
Figure 2-10 Time Settings Page
Description
Defines the time source by which the system time is set. The possible field values are:
SNTP — Indicates that the system time is retrieved from a SNTP server.
System Clock — Indicates that the system time is set locally by the device.
Displays the current date and time.
Description
Defines the IP address of primary SNTP server from which the system time is
retrieved.
Defines the IP address of secondary SNTP server from which the system time is
retrieved.
Defines the interval (in seconds) at which the SNTP server is polled for Unicast
information. The range is 60-86400 seconds. The Poll Interval default is 1024 seconds.
Description
Defines the current system date. The field format is Day/Month/Year.
Defines the current system time. The field format is HH:MM:SS based on the 24-hour
clock (Military Time) For example, 9:00PM is configured as 21:00:00.
. The SNTP settings are defied, and the device is updated.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents