Mira Sport Max with Airboost
9.0 & 10.8 kW
These instructions must be left with the user
Installation Guide
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mira Sport Max with Airboost 9.0 kW and is the answer not in the manual?

Questions and answers

Summary of Contents for Kohler Mira Sport Max with Airboost 9.0 kW

  • Page 1 Mira Sport Max with Airboost 9.0 & 10.8 kW These instructions must be left with the user Installation Guide...
  • Page 2 To enjoy the full potential of your new shower, please take time to read this guide thoroughly, and keep it handy for future reference. Products manufactured by Kohler Mira Ltd are designed to be safe provided, that they are installed used and maintained in good working order, in accordance with our instructions and recommendations.
  • Page 3: Important Safety Information

    9. DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. 10. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
  • Page 4: Pack Contents

    PACK CONTENTS   Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Mira Sport Max with Airboost Electric Shower   1 x Olive   1 x Compression Nut  ...
  • Page 5: Wiring Diagram

    WIRING DIAGRAM BROWN A BROWN E BLUE B BLUE F GREEN D HEATER GREEN C TANK RED K BROWN L RED J TERMINAL BLOCK GREEN D GREEN H BROWN M GREEN C AIR PUMP ORANGE P BLACK R GREY S INLET CONNECTOR ELECTRONIC ASSEMBLY...
  • Page 6: Specifications

    SPECIFICATIONS Sport Max with Airboost Variant Plumbing 10.8 Minimum Dynamic Pressure 70 kPa (0.7 bar) 100 kPa (1.0 bar) Maximum Dynamic Pressure * 500 kPa (5 bar) Minimum Static Pressure 20 kPa (0.2 bar) Maximum Static Pressure * 1000 kPa (10 bar) Maximum Inlet Temperature 30°C Minimum Inlet Temperature...
  • Page 7: Installation Requirements

    INSTALLATION REQUIREMENTS Please read the Important Safety Information and specifications sections at the front of this guide, and the requirements detailed in this section before installing the shower. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Plumbing The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice...
  • Page 8 15. A full bore/non restrictive servicing valve must be fitted in a readily accessible position adjacent to the shower to facilitate maintenance of the shower. DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure.
  • Page 9 WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Electrical The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
  • Page 10: Installation

    INSTALLATION Warning! Isolate the electrical and water supplies before installing the shower. Remove the three screws that Screws hold the cover on and remove Service the cover. Tunnel Remove the service tunnel. Using the installation template supplied, mark the positions of the three fixing holes.
  • Page 11 Determine the direction and route of the incoming water supply: falling (entering the shower from the top), or rising (entering the shower from the bottom). NOTE ! - DO NOT use an incoming supply entering the shower directly from the back. Add an elbow to the supply pipe and connect it as a rising or falling supply.
  • Page 12 Connect the inlet supply pipe to the inlet connector using Inlet the compression nut and olive Connector (supplied). Always provide mechanical support when making plumbing connections. Upon Olive completion of the installation ensure connections and back Compression case are not under any stress due to misaligned pipework or Inlet Supply electrical cables.
  • Page 13 Screws Ensure the earth bonding complies with relevant regulations. Cover Replace the service tunnel. Plug the multi-connector into the Multi- cover PCB socket Note! The Connector multi-connector will only locate correctly into the socket in one direction. Ensure the temperature control dial is aligned with the spindle Screw Spindle...
  • Page 14 Identify the different ends of the air pipe tube: • Air pipe adapter is inserted into the shower outlet • Air pipe diffuser is inserted into the showerhead Diffuser Adapter Fit the air pipe adapter into the outlet connector, then carefully tighten the shower hose onto the Note! Make outlet connector.
  • Page 15 COMMISSIONING TEMPERATURE Push START/STOP Turn temperature control Switch on the electrical button. Light in the button to the cold position. supply. illuminates. COLD 0 - 15 secs TEMPERATURE Push LOW button. Low Water flows freely within a Slowly turn the few seconds, temperature button illuminates.
  • Page 16 HIGH COLD 5 - 10 secs Temperature will rise slightly. Push HIGH button. High button illuminates COLD 5 - 10 secs TEMPERATURE Adjust temperature as required. Temperature will rise further. Flow rate will adjust automatically. Normal Flow AIRBOOST Airboost Enabled Push START/STOP button.
  • Page 17: Fault Diagnosis

    FAULT DIAGNOSIS In the event of a malfunction of the shower, the troubleshooting information below provides details on possible causes and remedies that may be carried out by qualified, competent personnel. Non-qualified personnel should refer to the fault diagnosis section in the users guide. WARNING There are no user serviceable components beneath the cover of the shower.
  • Page 18 Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Insufficient water supply Showerhead Minimum static pressure dripping. pressure for shut off. to ensure shut off and prevent dripping is 20 kPa (0.2 bar). Note! If other appliances are operating, static pressure may drop below 20 kPa (0.2 bar).
  • Page 19 Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Microswitch failure. Replace microswitch. change in Insufficient mains water Contact local water temperature pressure. company. between Low / Eco / Possible failure of flow Use a suitable device to High setting.
  • Page 20 SERVICING WARNING There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Before replacing any parts, ensure that the underlying cause of the malfunction has been resolved.
  • Page 21: Spare Parts

    SPARE PARTS 1746.528 Relay PCB 1746.436 Thermal Switch 1746.449 Terminal Block 1746.519 (9.0kW) 1746.520 (10.8kW) 1746.521 * Heater Tank 1746.522 * Flow Valve 1746.524 1746.527 Outlet Cover PCB Connector 1746.435 Inlet Clamp 406.27 Inlet Filter 1746.437 Coil 1746.434 Inlet Connector 1746.529 Air Pump 1746.448...
  • Page 22 NOTES...
  • Page 23 NOTES...
  • Page 24: Customer Service

    Otter House, Naas Road, Clondalkin, Dublin 22 assistance call our Customer Services Team. Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifications without notice. Mira is a registered trade mark of Kohler Mira Limited.
  • Page 25 Check out our full range of Showers Electric Showers Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps Grundfos Shower Pumps...