Summary of Contents for Kohler Mira Platinum Rear Fed
Page 1
Mira Platinum Rear Fed Shower Fittings For SPARES, ADVICE or REPAIRS please call us free on 0800 001 4040 (UK only) These instructions must be left with the user Installation and User Guide 1559389-W2-A...
Introduction Thank you for choosing a Mira showers. To enjoy the full potential of your new shower fittings, please take time to read this guide thoroughly, and keep it handy for future reference. Guarantee Mira Showers guarantee this product against any defect in materials or workmanship for a period of one year for the shower fittings.
Pack Contents 2 x Brackets 1 x Concealing Shroud 2 x End Plugs 1 x Shower Arm 1 x Backplate Assembly 1 x Slide Bar 1 x Fittings Pack 1 x Signature Overhead Assembly For Dual Outlet Product Only 1 x Hex Key 2 x 45 mm Screws 2 x Wall Plugs 2 x Hex Screws...
Page 4
General Please read the important safety information and the operation section of this guide before using the shower fittings. Failure to follow the instructions provided with this shower fittings will invalidate the guarantee. 1. Installation of the shower fittings must be carried out in accordance with these instructions by qualified, competent personnel.
Page 5
9. DO NOT install the shower or fittings where they may be exposed to freezing conditions. 10. The position of the shower fittings must provide a minimum air gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin.
Only Kohler Mira recommended accessories should be used. 10. When adjusting the handset mode, point the handset away from body and make sure that the water temperature has stabilised before continuing to shower.
Page 8
Installation: Shower Fittings Fit an isolating valve (not supplied) close to the digital mixing valve for ease of maintenance. Make sure that the outlet pipe work protrudes approx. 60 mm through a Dia 20 mm hole square to the finish wall surface.
Page 9
Secure the backplate to the wall so the foam seal is fully compressed. Foam Seal Important! Ensure arrow on backplate is oriented vertical as shown. Fit the collet and seal retainer. Re-check the pipe length. Collet Seal Retainer Flush pipework to clear all debris. 1 min Fit the o seal and elbow.
Page 10
Check for leaks. Fit the cover. Carefully lift the cover to locate the screw. Unscrew fully to lock Cover using the 2.5 mm hex key supplied. The slide bar should be fixed to the wall at a convenient height for all the users. It should be positioned so that water sprays down the Wall Bracket centre of the bath, or away from the opening...
Page 11
Drill into the marked holes to suit the wall fixings. Insert the wall plugs. Insert fixing screws through holes in wall brackets and fix to wall. DO NOT fully tighten at this stage. Use template to set correct distances between wall brackets. Fully tighten screws.
Page 12
End Cap Hose Washer Hose Hose Washer Fit the slide bar end caps into top and Important! Flush the pipework bottom of the slide bar assembly. before fitting the handset. Push and twist caps until they “click” and lock in place. Fit the one end of the shower hose to the right angled connector assembly and another end to the handset.
Page 13
Installation: Deluge Overhead The shower arm and deluge head should be fitted at a convenient height for all the family. It should be positioned so that water sprays down over the centre of the bath, or away from the opening of a shower cubicle. Ceiling Minimum Distance to Ceiling 35 mm...
Page 14
Backplate Compression Olive Olive Concealing Shroud Shower Compression Nipple Fit the olive and compression nipple Fit the concealing shroud onto the over the outlet pipe and tighten the shower arm. compression nipple to 25 ± 1Nm. Fit the compression nut and olive onto the shower arm.
Page 15
Cleaning Always read the IMPORTANT SAFETY INFORMATION for your shower. Cleaning the Showerhead Many household and commercial cleaners, including hand and surface cleaning wipes contain abrasives and chemical substances that can damage plastics, plating and printing and should not be used. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth.