Advertisement

Quick Links

Mira Atom ERD
With Moxie
For SPARES, ADVICE
or REPAIRS
Please call us on
0844 571 5000
(UK Only)
These instructions must be left with the user
Installation & User Guide
1
1232447-W2-A

Advertisement

Table of Contents
loading

Summary of Contents for Kohler Mira Atom ERD

  • Page 1 Mira Atom ERD With Moxie For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) These instructions must be left with the user Installation & User Guide 1232447-W2-A...
  • Page 2: Recommended Usage

    INTRODUCTION Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. GUARANTEE For domestic installations, Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of five years from the date of purchase (shower fittings and Moxie speaker for one year).
  • Page 3 Children should be supervised to ensure that they do not play with the product. DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. DO NOT fit any form of outlet flow control. Only Mira recommended outlet fittings should be used.
  • Page 4: Specifications

    Bluetooth ® SIG, Inc. and any use of such marks by Kohler Co. is under license. Other trademarks and trade names are those of their respective owners. CE Radiation Exposure Statement for Mobile Devices This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment.
  • Page 5: Installation

    Recommended Hot Supply 0°C to 65°C (Note! The mixing valve can operate at temperatures up to 85°C for short periods without damage. However for safety reasons it is recommended that the maximum hot water temperature is limited to 65°C). Minimum Recommended Differential 12°C at desired flow rates.
  • Page 6 General Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. The installation must comply with the “Water Supply Regulations 1999 (Water Fittings)” or any particular regulations and practices, specified by the local water company or water undertakers. Note! Make sure that all site requirements correspond to the information given in section: ‘Specifications’.
  • Page 7 Installation of the Bar Valve Important! Before installing the pipework, please ensure that there is a minimum of 1065mm height clearance to allow for the rigid riser and overhead to be installed above. If installing in a restricted height area, a shorter riser rail can be ordered as a spare part. The thermostatic bar valve should be installed where it will be supported by fixed pipework.
  • Page 8 Installation of the Shower Fittings Slide the hose retaining ring and the clamp bracket onto the middle bar, and then screw the middle and lower bar sections together. Screw the riser arm to the middle and lower bar section. Push the riser bar into the top of the bar valve. Note! The riser bar must be located correctly, push down firmly to seat it.
  • Page 9 Wall Fixing Bracket Grub Screw Riser Arm Fixed Showerhead Mounting Boss Riser Wall Fixing Bracket Concealing Middle Bar Cover Showerhead Clamp Bracket Hose Hose Retaining Ring Lower Bar Note! 'O' Seal is located inside Lower Bar Valve Grub Screw 1232447-W2-A...
  • Page 10 COMMISSIONING Bar Valve Commissioning Maximum Temperature Setting Before using the shower, the maximum temperature must be checked to make sure that it is at a safe level. It has been preset to a safe showering temperature under ideal conditions at the factory, appropriate for most systems.
  • Page 11 Wireless Speaker Pairing 1 sec If required set your BLUETOOTH to ON. ® Press the power button for 1 second to power Set your music device to midrange volume the wireless speaker ON or OFF. before connecting to the wireless speaker The light will blink blue to indicate pairing Use the USB cable provided to recharge your mode.
  • Page 12: Operation

    OPERATION Bar Valve Decrease Temperature Temperature Override Button Increase Temperature Temperature Selector Knob Flow Selector Knob Adjusting the Temperature The temperature is controlled by rotating the temperature selector knob.For safety reasons, the temperature is limited by an override stop. To obtain a higher temperature, press the override button on the temperature selector knob and continue to rotate the knob.
  • Page 13: Fault Diagnosis

    FAULT DIAGNOSIS If you require a Mira trained service engineer or agent, refer to section: ‘Customer Services’. Bar Valve Fault Diagnosis Symptom Cause Recommended Action Water too hot or too Inlets reversed (hot supply to Rework inlet pipework. cold cold supply). Check filters for any blockage.
  • Page 14 Symptom Cause Recommended Action The status LED is not Battery is not charged. Use the USB cable provided to illuminated. recharge the battery. N o s o u n d p l a y s The song is paused. Make sure the song is playing. through the speaker..
  • Page 15: Spare Parts

    SPARE PARTS 1836.182 Riser Arm 1736.733 Wall Fixing 1736.732 Middle Bar 1836.171 1703.203 Concealing Plates Clamp Bracket 1836.180 Z Connectors 1740.601 Overhead - White/Chrome 1836.247 (does not include Moxie Speaker) Plug 1770.609 Multi Mode Handset 1836.174 Inlet Seal/ 632.73 Filter Hose Seal (x2) 1836.244 1703.199...
  • Page 16 (excludes Eire). Ring 01922 471763 for more details. Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifi cations without notice. FM 14648 1232447-W2-A © Kohler Mira Limited, February 2014...

Table of Contents