Advertisement

Quick Links

Temperature Relays and MINIKA®
Operating Manual URB40
For more information and help about this product please scan the
choose the following link:
Operating manual, Quick guide, Datasheet, Connection diagram, CAD Data
Firmwareupdates, FAQ, Videos about installation and settings, Certificates
- Relay expasion box for UR-Devices
URB40
Zeichnungsnummer
Mains Monitoring
Digital Panelmeters MINIPAN®
URB40
Switching Relays and Controls
Page 1 / 10
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstr.13, 74523 Schwäbisch Hall, Germany
+ 49 791 504-0,
info@ziehl.de,
Measuring Transducers
Grid- and Plant Protection
updated: 2024-01-24 / dr
from Firmware: 0-00
QR-Code
or
www.ziehl.de
www.ziehl.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the URB40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZIEHL URB40

  • Page 1 ZIEHL industrie – elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA® Mains Monitoring Digital Panelmeters MINIPAN® Switching Relays and Controls Measuring Transducers Grid- and Plant Protection updated: 2024-01-24 / dr...
  • Page 2: Table Of Contents

    Overview of the predefined standard ranges ......Fehler! Textmarke nicht definiert. 10 Diagram for setting a predefined range ..........Fehler! Textmarke nicht definiert. 11 Error search ............................7 12 Technical data ............................8 13 Type V4 ..............................10 14 Disposal ..............................10 URB40 Zeichnungsnummer Page 2 / 10 www.ziehl.de...
  • Page 3: General Notes

    5 LED Termination status • On: Bus termination is active • Off: Bus termination is inactive 6 Button • Pressed for more than 2 s: Reset • Pressed for more than 10 s: Factoyr reset • URB40 Zeichnungsnummer Page 3 / 10 www.ziehl.de...
  • Page 4: Factory Setting

    4 Application and short description The Universal-Relay Box URB40 is an expansion box for UR and other Client Devices, which can be used to control up to four additional relay outputs via Modbus RTU. The URB40 monitors the communication between the devices and allows for each relay output to be placed in a predefined state in case of a timeout.
  • Page 5: Connecting Diagram

    6 Connecting diagram URB40 Zeichnungsnummer Page 5 / 10 www.ziehl.de...
  • Page 6: Important Information

    • connecting wires refer to the connection plan to prevent miss-operation and malfunction. A circuit-breaker or switch must be situated within easy reach of the unit and fused. Installation excess current protection should be ≤ 10 A. URB40 Zeichnungsnummer Page 6 / 10...
  • Page 7: Commissioning

    9.1 Connecting to the Bus-System 9.2 Transmission parameters setting The URB40 is configured via an external device connected to the RS485 interface. The communication protocol at use is Modbus RTU. All default parameters for establishing an initial connection can be viewed here.
  • Page 8: Technical Data

    8760 h/y Failure rate (FIT) Tu = 40 °C Tu = 60°C Tu = 80°C 1007 FIT 1965 FIT 4232 FIT Tu = Tref (component not in operation) 113 Jahre 58 Jahre 27 Jahre URB40 Zeichnungsnummer Page 8 / 10 www.ziehl.de...
  • Page 9 1 x 0,34 - 1,5 mm² / AWG 22 - 14 Stranded wire with insulated ferrules 1 x 0,1 - 1,0 mm² / AWG 27 - 16 Abisolierlänge 8 mm 0,5 Nm torque Subject to technical changes URB40 Zeichnungsnummer Page 9 / 10 www.ziehl.de...
  • Page 10: Type V4

    13 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provisions. ZIEHL is registered with the EAR Foundation under WEEE no .: DE 49 698 543. URB40 Zeichnungsnummer Page 10 / 10...