Advertisement

Quick Links

Instructions for use
SMARTmatic PROPHY S31 – 1.011.6760
SMARTmatic PROPHY S31 K – 1.011.6761
SMARTmatic PROPHY S33 – 1.011.6800

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1.011.6760 and is the answer not in the manual?

Questions and answers

Summary of Contents for KaVo 1.011.6760

  • Page 1 Instructions for use SMARTmatic PROPHY S31 – 1.011.6760 SMARTmatic PROPHY S31 K – 1.011.6761 SMARTmatic PROPHY S33 – 1.011.6800...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH KaVo Dental GmbH Bismarckring 39 Bismarckring 39 88400 Biberach 88400 Biberach Germany Germany Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 Table of contents Table of contents 1 User instructions....................... 2 Safety ..........................2.1 Infection hazard......................7 2.2 Improper use ....................... 7 2.3 Technical condition......................
  • Page 4: User Instructions

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 1 User instructions 1 User instructions Dear user, Congratulations on purchasing this KaVo quality product. By following the notes below you will be able to work smoothly, economically and safely.
  • Page 5 Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 1 User instructions Serial number UDI symbol Manufacturer Note: Please note accompanying documents Follow the electronic instructions for use HIBC Code...
  • Page 6 Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 1 User instructions WARNING In cases which – if not prevented – can lead to death or severe injury. CAUTION In cases which –...
  • Page 7: Safety

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 2 Safety | 2.1 Infection hazard 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
  • Page 8: Accessories And Combination With Other Equipment

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 2 Safety | 2.4 Accessories and combination with other equipment ▪ Damage (e.g., from dropping) ▪ Irregular running noise ▪ Excessive vibration ▪...
  • Page 9 Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 2 Safety | 2.6 Service and repair 4 Have the service and testing tasks carried out according to the Medical Device Operator Ordinance.
  • Page 10: Product Description

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 3 Product description | 3.1 Intended use 3 Product description SMARTmatic PROPHY S31 (Mat. no. 1.011.6760) SMARTmatic PROPHY S31 K (Mat. no. 1.011.6761) SMARTmatic PROPHY S33 (Mat.
  • Page 11: Technical Specifications S31, S31 K (Without Light)

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 3 Product description | 3.2 Technical specifications S31, S31 K (without light) ▪ the applicable accident prevention regulations ▪ these Instructions for use According to these regulations, the user is required: ▪...
  • Page 12: Transportation And Storage Conditions

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 3 Product description | 3.4 Transportation and storage conditions 3.4 Transportation and storage conditions CAUTION Startup after refrigerated storage. Malfunction.
  • Page 13: Startup And Shut Down

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 4 Startup and shut down 4 Startup and shut down WARNING Hazard from contaminated products. Patients, users or third parties could be infected by contaminated medical devices.
  • Page 14: Operation

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 5 Operation | 5.1 Attaching the medical device 5 Operation WARNING The patient swallows or aspirates loose parts or substances.
  • Page 15 Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 5 Operation | 5.3 Inserting the dental bur NOTE Only use prophy cups and polishing brushes or supports with Snap-On func- tion in accordance with DIN EN ISO 13295, support type 5.
  • Page 16: Removing The Dental Bur

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 5 Operation | 5.4 Removing the dental bur 5.4 Removing the dental bur WARNING Rotating dental bur. Cuts, infection and burn injury.
  • Page 17: Checking For Malfunctions And Troubleshooting

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 6 Checking for malfunctions and troubleshooting | 6.1 Checking for malfunctions 6 Checking for malfunctions and troubleshooting 6.1 Checking for malfunctions CAUTION Overheating of the device.
  • Page 18 Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 6 Checking for malfunctions and troubleshooting | 6.2 Troubleshooting 4 Spray a lint-free cloth with KaVo Spray, apply it to the new O-rings and in- sert them in the recesses.
  • Page 19: Reprocessing Steps In Accordance With Iso 17664-1 / Iso 17664-2

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.1 Preparations at the site of use 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 7.1 Preparations at the site of use...
  • Page 20: Manual Pre-Cleaning

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.2 Manual reprocessing CAUTION Never reprocess this medical device in an ultrasonic cleaner.
  • Page 21: Manual Drying

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.3 Automated reprocessing 4 Allow the disinfectant to act for 5 minutes.
  • Page 22: Care Products And Systems - Servicing

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.4 Care products and systems - Servicing NOTE Please comply with the instructions for use of the washer disinfector.
  • Page 23: Sterilisation

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.6 Sterilisation 7.6 Sterilisation Sterilisation in a steam steriliser (autoclave) in...
  • Page 24: Optional Aids And Consumables

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 8 Optional aids and consumables 8 Optional aids and consumables Available from specialised dental dealers. Material summary Mat.No. INTRA Instrument stand 3.005.5204...
  • Page 25: Terms And Conditions Of Warranty

    Instructions for use SMARTmatic PROPHY S31 – 1.011.6760, SMARTmatic PROPHY S31 K – 1.011.6761, SMART- matic PROPHY S33 – 1.011.6800 9 Terms and conditions of warranty 9 Terms and conditions of warranty This KaVo medical device is subject to the following warranty conditions:...

Table of Contents