Devices

Adding a Device
1. Make sure devices are connected and green lights
are illuminated.
2. Log in as an administrator.
3. Use ↑ and ↓ keys to select Devices and press
ENTER.
4. Select a device from the list and press ENTER.
NOTE: When new Devices are first connected,
they will appear in the Device list with the
name "CONFIG PUMP"
TIP: A red indicating light will blink on the
currently selected device
5. Type in a name for the device
6. Select the Device Type:
• AODD Pump - Constant output
• Valve - Constant output
• Piston Pump - Pulsed output with user
defined stroke Volume and ON/OFF cycle
Time.
7. If Piston Pump is selected, enter stroke volume
and ON/OFF Time
8. If you wish to prime, press the START key to turn
the Device output on and press STOP when to
turn off.
WARNING:
!
Pressing the START key on this screen will cause
the output to turn on and the pump to run!
Wear PPE and be ready to contain the flow of
chemical in an appropriate vessel!
9. Press the ESC key to exit.
10. When prompted to save changes, press ← for Yes
or → for No.
Page 10 of 33
ALX-ELITE User Manual
Edit Devices
>0555-CONFIG PUMP
0875-CONFIG PUMP
0689-Water (Red)
Editing Device #0555
Demo Chemical
Type:
AODD Pump
Prime (Start/Stop)
Edit Calibration
Replace Controller
(DELETE Entry)
Editing Device #0555
Demo Chemical
Type:
Piston Pump
Prime (Start/Stop)
Volume: 000.00oz
ON Time:
OFF Time: 00.0s
Replace Controller
(DELETE Entry)
Save changes?
Are you SURE?
Press <= for Yes
Press => for No
00.0s