Table A5 - DoubleSmart-Control - Advanced parameters
Parameter
156. S1 input –
This parameter defines the value
Switch ON value
sent with the Switch ON command
sent to 2
nd
associa-
to devices in the 2
tion group
group when using S1 input.
157. S1 input –
This parameter defines the value
Switch OFF value
sent with the Switch OFF command
sent to 2
associa-
to devices in the 2
nd
tion group
group when using S1 input.
158. S1 input –
This parameter defines the value
Double Click value
sent with the Double Click com-
sent to 2
associa-
nd
mand to devices in the 2
tion group
tion group when using S1 input.
159. S2 input –
This parameter defines the value
Switch ON value
sent with the Switch ON command
sent to 3
associa-
to devices in the 3
rd
tion group
group when using S2 input.
160. S2 input –
This parameter defines value sent
Switch OFF value
with Switch OFF command to de-
sent to 3
associa-
vices in 3
rd
tion group
using S2 input.
161. S2 input –
This parameter defines value sent
Double Click value
with Double Click command to de-
sent to 3
associa-
vices in 3
rd
tion group
using S2 input.
This parameter determines the type
162. Q1 output type
of Q1 output.
This parameter determines the type
163. Q2 output type
of Q2 output.
164. Lock simultane-
When the lock is enabled, both
ous switching of Q1
outputs cannot be turned on at the
and Q2 outputs
same time.
12
Description
association
nd
association
nd
nd
associa-
association
rd
association group when
rd
association group when
rd
Available setting
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
0 – Normally Open (relay contacts are opened
when turned off and closed when turned on)
1 – Normally Closed (relay contacts are closed
when turned off and opened when turned on)
0 – Normally Open (relay contacts are opened
when turned off and closed when turned on)
1 – Normally Closed (relay contacts are closed
when turned off and opened when turned on)
0 – lock disabled
1 – lock enabled
Default
Parameter
setting
size
255
2 [bytes]
0
2 [bytes]
99
2 [bytes]
255
2 [bytes]
0
2 [bytes]
99
2 [bytes]
0 (Normally
1 [byte]
Open)
0 (Normally
1 [byte]
Open)
0 (lock dis-
1 [byte]
abled)