2500W load. Plug-Control is equipped with a power and energy metering function. It uses a LED ring to visualize the current load with colour changing il- lumination and operating mode. This is the smallest and most attractive device of this type available in the world.
5. Wait for the removing process to end. 6. Successful removing will be confirmed by the Z-Wave controller’s message. Notes Removing Plug-Control from the Z-Wave network restores all the default parameters of the device, but does not reset power metering data.
Page 4
POWER AND ENERGY CONSUMPTION Plug-Control allows to monitor the active power and energy consumption. Data is sent to the main Z-Wave controller, e.g. Home Center. Mea- suring is carried out by the most advanced micro-controller technology, assuring maximum accuracy and precision.
Page 5
3rd Association Group – “On/Off (Power)” devices in this group will be switched on or off depending on the current load (uses Basic command class). Plug-Control in 2nd and 3rd group allows to control up to 10 regular or multichannel devices per an association group. “LifeLine” group is reserved solely for the controller and hence only 1 node can be assigned.
ADVANCED PARAMETERS Plug-Control allows to customize its operation to user’s needs. The settings are available in the interface of the Z-Wave controller. Table A3 - Plug-Control - Advanced parameters Parameter: 1. “Always On” mode Description: In this mode Plug-Control will turn on connected device permanently and will stop reacting to attempts of turning it off (through Z-Wave network or pushing the B-button).
Page 7
11. The higher the value of parameter 12, the fewer reports the device will send. By default Plug-Control sends up to 5 reports each 30 seconds, provided the power load changes by 15%. Available settings:...
Page 8
This parameter defines how Plug-Control will respond to alarms (device’s status change). In case of values 1 or 2 Plug-Control is operating normally and LED ring signals an alarm through time defined in parameter 32 or until the alarm is cancelled.
Page 9
Parameter: 41. LED ring colour when controlled device is on Description: When set to 1 or 2, LED ring colour will change depending on active power and parameter 40. Other colours are set permanently and do not depend on power consumption. Available settings: 0 - illumination turned off completely 1 - colour changes continuously depending on active power...
Page 10
Notes: • Overload safety switch functionality is not an overload safety protection nor a short circuit protection. Circuit needs additional short circuit and overload protection! • In extreme cases, reports may be sent every second if rapid and significant power load changes occur. Frequent reporting may overload the Z-Wave network so values of parameters 10 and 11 should reflect significant changes in power load only.
The product Plug-Control is produced by Nice S.p.A. (TV). Warnings: - All technical specifications stated in this section refer to an ambient temperature of 20 °C (± 5 °C) - Nice S.p.A. reserves the right to apply modifications to the product at any time when deemed necessary, while maintaining the same functionalities and intended use.
Caution! – local legislation may envisage serious fines in the event of abusive disposal of this product. DECLARATION OF CONFORMITY Hereby, Nice S.p.A., declares that the radio equipment type Plug-Control is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.niceforyou.com/en/support...
Page 13
Nice SpA Oderzo TV Italia www.niceforyou.com info@niceforyou.com...