SIMPLICITY PLUS INSTALLATION MANUAL
20. STANDBY BATTERY REQUIREMENTS
The Following Table shows the Quiescent, Fault & alarm currents of the main parts of a Simplicity Fire Alarm System
DEVICE
SIMPLICITY PLUS 64 Fire Alarm Panel
SIMPLICITY PLUS 126 Fire Alarm Panel
SIMPLICITY PLUS 252 Fire Alarm Panel
Premier Addressable REPEATER PANEL
Fyreye MKII Addressable Optical Smoke Detector
Fyreye MKII Addressable Heat Detector
Fyreye MKII Fixed Temperature Heat Detector
Fyreye MKII Addressable Opto-Heat Detector
Zeta Addressable Call Point (EN54)
Zeta Weatherproof Addressable Call Point
Zeta Addressable Input Module with SCI
Zeta Addressable Input/ Output Module with SCI
Zeta Addressable Input/ Output Module with SCI –
mains switching
Zeta Sounder Control Module
Zone Monitor Unit
Fyreye Addressable Beam Detector (5-50m)
Sandwich Sounder Base
Zeta Addressable Maxitone Sounder
Zeta Addressable Maxitone Sounder flasher
Zeta Addressable Xtratone Sounder
Zeta Addressable Maxitone Sounder flasher
Zeta Addressable Remote LED Indicator
Zeta Conventional wire Remote LED
Conventional Sounders (via a sounder Control Circuit)
Zeta Conventional Maxitone Sounder
Zeta Conventional Miditone Sounder
Zeta Conventional Securetone Sounder
Zeta Conventional Megatone Sounder
Zeta Conventional Flasher
Zeta Conventional Sounder Flasher
Zeta Conventional 6" Bells
Zeta Conventional 8" Bells
Conventional Detectors (via a Zone Monitor)
Fyreye MKII Conventional Optical Detector
Fyreye MKII Conventional Heat Detector (A2R)
Fyreye MKII Conventional Heat Detector (A2S)
Fyreye MKII Conventional Opto-Heat Detector
GSM COMMUNICATOR
TCP-IP COMMUNICATOR
* The Simplicity can only power 1 repeater. Any subsequent ones will need a separate power supply.
Approved Document No: GLT.MAN-107
Issue 3.16
Author: NRPJ
www.acornfiresecurity.com
PRODUCT CODE
SP-64
SP-126
SP-252
REP-AD
MKII-AOP
MKII-AHR
MKII-AHF
MKII-AOH
ZT-CP3/AD
ZT-CP3/AD/WP
ZAI-MI
ZAIO-MI
ZAIO-MI /230
ZASC-MI
ZAZM-MI
ZT-BEAM + SMM/B
MKII-SSB
MKII/AMT
MKII/AMTF
MKII/AXT
MKII/AXTF
MKII-ARL/W(C)
MKII-RL/W(C)
ZMT/8
ZMD/8
ZST/8
ZIDC
ZFL2RR
ZLT/8RR
ZTB6B/24
ZTB8B
MKII-OP
MKII-HR
MKII-HF
MKII-Oh
GSM-COM
TCP-IP
Date: 21/09/2017
www.acornfiresecurity.com
MAX
I
I
I
Q
FLT
ALM
(MA)
(MA)
(MA)
LOOP
90
105
115
N/A
90
105
115
N/A
115
120
130
N/A
200
220
220
N/A
0.5
N/A
5.0
126
0.5
N/A
5.0
126
0.5
N/A
5.0
126
0.5
N/A
5.0
126
0.45
N/a
2.3
126
0.45
N/a
2.3
126
1.0
1.25
3.6
32
1.0
1.25
2.0
16
0.9
2.8
19
10
0.6
0.6
0.8
16
3.5
12.6
13.2
10
5
7
9
16
0.6
N/a
7.5
32
0.6
N/a
7.0
32
0.6
N/a
10.6
24
0.6
N/a
7.5
32
0.6
N/a
7.5
24
0.45
N/a
2.1
32
0
N/a
10
32
0
N/a
15
N/a
0
N/a
15
N/a
0
N/a
15
N/a
0
N/a
200
N/a
0
N/a
90
N/a
0
N/a
110
N/a
0
N/a
25
N/a
0
N/a
35
N/a
0.06
N/a
25
N/a
0.04
N/a
25
N/a
0.04
N/a
25
N/a
0.06
N/a
25
N/a
200
500
500
N/A
80
80
80
N/A
PAGE 43
.
MAX
PER
PER
SYSTEM
1
1
1
4*
252
252
252
252
252
252
64
32
20
32
20
32
64
64
48
64
48
64
64
N/a
N/a
N/a
N/a
N/a
N/a
N/a
N/a
N/a
N/a
N/a
N/a
1
1
Need help?
Do you have a question about the SIMPLICITY PLUS SP-64/M and is the answer not in the manual?